RE8RA21FU TELEMECANIQUE, RE8RA21FU Datasheet - Page 6

TIMER, OFF-DELAY 3-300S

RE8RA21FU

Manufacturer Part Number
RE8RA21FU
Description
TIMER, OFF-DELAY 3-300S
Manufacturer
TELEMECANIQUE
Datasheet

Specifications of RE8RA21FU

Contact Configuration
SPCO
Nom Input Voltage
240VAC
Delay Time Range
3s To 300s
Relay Mounting
DIN Rail
Contact Current Ac Max
8A
Contact Current Dc Max
8A
Contact Voltage Ac Max
250V
References :
pages 2/38 and 2/40
Dimensions :
page 2/42
Schemes, setting-up :
pages 2/39, 2/41 and 2/43
Time delay characteristics
Setting accuracy
Repeat accuracy
Influence of voltage
Influence of temperature
Immunity to
micro-breaks
Minimum control pulse
Reset time
Output circuit characteristics
Maximum switching voltage
Mechanical durability
Current limit Ith
Rated operational limits at 70 C
Conforming to IEC 60947-5-1/1991
and VDE 0660
Minimum switching capacity
Contact material
Remote control input characteristics
Signal delivered by
control input Y1
this input and the power supply
a.c. load
Curve 1
Electrical durability of contacts on resistive
load in millions of operating cycles
A
Example:
An LC1-F185 contactor supplied with 115 V/50 Hz for a consumption of 55 VA or a current
consumption equal to 0.1 A and cos
For 0.1 A, curve 1 indicates a durability of approximately 1.5 million operating cycles.
As the load is inductive, it is necessary to apply a reduction coefficient k to this number of
cycles, as indicated by curve 2.
For cos
The electrical durability therefore becomes:
1.5 10
0,01
0,1
10
RE8-RBiiBUTQ
1
No galvanic insulation between
0
6
operating cycles x 0.6 = 900 000 operating cycles
1
= 0.3: k = 0.6
2
3
4
A
Current broken in A
5
6
7
= 0.3
Zelio Time - timing relays
Relay output, width 22.5 mm, optimum
General characteristics
As % of the full scale value
In the voltage range, 0.9…1.1 Un
In millions of operating cycles
AC-15
DC-13
No-load voltage
Switching current
Maximum distance
Compatibility
8
Curve 2
Reduction factor k for inductive loads
(applies to values taken from the
durability curve opposite)
0,9
0,8
0,7
0,6
0,5
0,4
0,3
1
1
0,8
0,6 0,5
Power factor on breaking (cos )
(continued)
0,4
ms
ms
A
A
mA
m
ms
V
A
0,3
< 1 %
< 2.5 %
< 0.2 %/ C
3
26 (except RE8-YG: 60)
50
z 250
20
8
24 V
3
2
12 V/10 mA
Nickel Silver 90/10
Supply voltage
< 10
50
a 2-wire sensors with leakage current < 1 mA
20 %
0,2
A
1
2
3
d.c. load
Load limit curve
+
RE8-RBiiBUTQ
L/R = 20 ms
L/R with load protection diode
Resistive load
300
200
100
RE8
115 V
3
0.2
50
40
30
20
10
K
0,1
0,2
1
2
0,5
3
250 V
3
0.1
1
Te
2
A
5
Current in A
10
20
2/37
2