24A.1-10SDOD AMPERITE, 24A.1-10SDOD Datasheet

TIME DELAY RELAY, DPDT, 10SEC, 24VAC

24A.1-10SDOD

Manufacturer Part Number
24A.1-10SDOD
Description
TIME DELAY RELAY, DPDT, 10SEC, 24VAC
Manufacturer
AMPERITE
Datasheet

Specifications of 24A.1-10SDOD

Contact Configuration
DPDT
Nom Input Voltage
24VAC
Delay Time Range
0.1s To 10s
Timing Adjustment
Knob
Relay Mounting
Plug In
Supply Voltage
24VAC
No. Of Poles
2
Mounting Type
Plug-In
Timing Mode:
Upon the application of input voltage the relay immediately energizes. The timing cycle
begins when input voltage is removed. When the timing cycle is complete, the relay will
de-energize. The relay contacts will reset when input voltage is reapplied.
Timing Diagram:
Contact Information:
Arrangement: 2 form C (DPDT) - Diagrams C & D
Contact Material: Gold Clad Silver Alloy
Rating (Resistive):
Maximum Switching Power - 1000 VA, 90W
Maximum Switching Voltage - 250V AC, 48V DC
Maximum Switching Current - 4 Amperes
Nominal Switching Capacity - 4A 250V AC, 3A 30V DC
UL/CSA Ratings - 4A 1/20 HP 125, 250V AC, 3A 30V DC
Expected Life @ 25°C:
100 Million operations, Mechanical
Electrical: 100,000 operations at 4A 250V AC
200,000 operations at 3A 30V DC
Environmental Information:
Temperature Range: Ambient: -40°C to +65°C (-40°F to +149°F)
DOD Series
TDR
Solving your relay requirements since 1922
… Solid state analog circuitry
… True delay on dropout: Timing cycle after
power removal
… DPDT (2 form C) isolated 4 ampere relay
contacts
… Timing selection: Knob adjustable or Fixed
… Numerous models timing from 0.1 secs. to 300
secs.
… UL File #E96739 (M)
… CSA File #LR62586
West New York, NJ 07093
www.Amperite.com
567 52nd Street
(800) 752-2329
Amperite Co.
P.O. Box 329

Related parts for 24A.1-10SDOD

24A.1-10SDOD Summary of contents

Page 1

... DPDT (2 form C) isolated 4 ampere relay contacts … Timing selection: Knob adjustable or Fixed … Numerous models timing from 0.1 secs. to 300 secs. … UL File #E96739 (M) … CSA File #LR62586 Amperite Co. 567 52nd Street P.O. Box 329 West New York, NJ 07093 (800) 752-2329 www.Amperite.com ...

Page 2

... Voltage: AC units- 12V, 24V, and 120V; DC units- 12V, 24V, 48V and 110V. Other voltages are available. Power Requirement: AC units less; DC units: 2 Watts or less Transient Protection: 1 JOULE MOV Polarity Protection units - Yes Input Voltages & Limits: Amperite Co. 567 52nd Street P.O. Box 329 West New York, NJ 07093 (800) 752-2329 www.Amperite.com ...

Page 3

... Wiring Diagrams: Ordering Information: Definition of a part number for the Amperite DOD Series Time Delay Relay. Example: A: Denotes nominal input voltage. Voltages Available: 12, 24 & 120V AC; 12, 24, 48 & 110V DC. Custom Voltages are available. B: Denotes type of input current required for operation: Amperite Co ...

Page 4

... E: Denotes use of seconds or minutes in timing value(s seconds minutes. F: Enter "L" if optional 11-pin spade terminals are required (Diagrams B & D). G: Denotes DPDT (2 form C) 4 amp delay on dropout DOD Series Time Delay Relay. Solving Your Relay Requirements Since 1922 Amperite Co. 567 52nd Street P.O. Box 329 West New York, NJ 07093 (800) 752-2329 www ...

Related keywords