HW-C10 IDEC, HW-C10 Datasheet

no-image

HW-C10

Manufacturer Part Number
HW-C10
Description
CONTACT BLOCK, 1NO, 10A, SCREW
Manufacturer
IDEC
Series
HWr
Datasheet

Specifications of HW-C10

No. Of Poles
1
Contact Current Max
10A
Contact Voltage Ac Max
600V
Contact Voltage Dc Max
220V
Switch Terminals
Screw
Circuitry
SPST-NO
For Use With
Idec HW Series 22mm Switches
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
A3
ø22mm - HW Series
A3-52
HW: The Best Engineered Switch in the World
Key features include:
• Locking lever removable contact blocks
• Finger-safe IP20 contacts as standard, other terminal
• Tamperproof construction
• All E-stops meet EN418 and are compliant with SEMI
• Worldwide approvals
• Easy to assemble
• Available assembled or as sub-components
• Choice of black plastic or metallic front bezels
• Incandescent or LED illumination
• Transformer or full voltage
• Slow make double break self cleaning contacts
File No. E68961
styles available
S2 standards
www.idec.com
File No. LR92374
HW Series — 22mm IEC Style Global Pushbuttons
Oiltight Switches & Pilot Devices
Registration No. R9551089 (E-stops)
Registration No. R50054316 (Dual Pushbuttons)
Registration No. J9650511 (Pilot Lights)
Registration No. J9551458 (all other switches)
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
IDEC’s HW switches are “The best engineered switch in the world” for a
reason. Carrying the CE mark, UL, CSA, CCC (Chinese), and TUV approv-
als, these switches are designed for use in almost any part of the world.
Complete with finger-safe contact blocks offering IP20 protection, these
7/8" (22mm) switches include illuminated and non-illuminated
pushbuttons, pilot lights, selector switches, and emergency stop
switches.
All switches also incorporate mechanically keyed safety locking levers,
ensuring correct installation and maintaining safety in high-vibration
applications.
Certificate No.
2005010305145656

Related parts for HW-C10

HW-C10 Summary of contents

Page 1

... A3-52 www.idec.com Oiltight Switches & Pilot Devices IDEC’s HW switches are “The best engineered switch in the world” for a reason. Carrying the CE mark, UL, CSA, CCC (Chinese), and TUV approv- als, these switches are designed for use in almost any part of the world. ...

Page 2

... IEC6068-2-7 Class 0 conforming to IEC60536 IP65 (from front of the panel) IP20 (Type HW-F contact block) NEMA 3R, 3S, 4, 4X, 5, 12, 13 (from front of panel) Momentary pushbuttons: 5,000,000 (900 operations per hour), All other switches: 500,000 3 for switches not using a transformer, 2 for switches using a transformer AC-15: A600 250V (NO, NC, NO-EM, NC-LB) DC-13: P600 125V ...

Page 3

... HW Series Part Numbers: Non-Illuminated Pushbuttons Contact Style A3 Round Flush 1NO 1NC 1NO-1NC 2NO 2NC 2NO-2NC Round Extended 1NO 1NC 1NO-1NC 2NO 2NC 2NO-2NC 29mm Mushroom Head 1NO 1NC 1NO-1NC 2NO 2NC 2NO-2NC 40mm Mushroom Head 1NO 1NC 1NO-1NC 2NO 2NC ...

Page 4

... Color Code Black B Green G HW4B-A4- Red R Blue S White W Yellow Y Grey N* – *Grey is available for round flush only. ø22mm - HW Series A3 Plastic Bezel Metal Bezel HW2B-M1- – HW2B-A1- – HW2B-M2- – HW2B-A2- – Contacts Part Number 1NO HW-CBF10 1NC HW-CBF01 1NO/1NC HW-CBF11 2NO ...

Page 5

... HW-G01 Ø 29mm HW-G10R HW-G01R Mushroom Cap (early make) (late break) HW1A-B3- Ø40mm HW-C10 HW-C01 Mushroom Cap HW-C10R HW-C01R HW1A-B4- (early make) (late break) Square Flush HW2A-B1- TW-DB Square Extended HW2A-B2- Part Number: Contact Block Mounting Adaptor (safety lever lock included) Style 1 ...

Page 6

... For sub-assembly part numbers, see next page. 9. All HW series E-stops comply with EN418, the IEC “E-Stop Addendum to the Low Voltage Directive,” this includes “tamper proof” operation whereby a change of contact state is not possible by “teasing” or “floating” the operator. ...

Page 7

... All HW Series Emergency Stop operators include non-removable color caps. 3. All HW Series Emergency Stop operators comply with EN418 “E-Stop Addendum to the Low Voltage Directive” (when used as part of a complete HW series Emergency Stop Pushbutton). 4. All HW series Emergency Stop switches comply with SEMI S2 standards. ...

Page 8

... HW-G10-MAU HW-G01-MAU (gold con- (gold con- tacts) tacts) HW-C10 HW-C01 HW-C10R HW-C01R (early make) (late break) TW-DB 1. All assembled part numbers in catalog include standard (HW-F...) contacts. (except unibody) 2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex ...

Page 9

... HW Series Part Numbers: Emergency Stop Stations Description A3 Ø 40mm Pushlock Turn Reset Ø 29mm Pushlock Turn Reset Ø 40mm Push-Pull Reset Ø 40mm Pushlock Key Reset 1. * Available in Red only. 2. Maximum of two contact blocks. 3. Available as completed unit only. 4. Box is supplied with yellow top and black bottom only. ...

Page 10

... AC HW1P-2FM4 - HW4P-2FM4 - 480V AC HW1P-2FT8 - HW4P-2FT8 - 110V DC HW1P-2D2 - HW2P-1FQ - - HW2P-1FH2 - 120V AC 240V AC HW2P-1FM4 - 480V AC HW2P-1FT8 - 110V DC HW2P-1D2 - LED HW1P-5Q 4- Incandescent HW1P-5Q 7- Lamp Type Code Lamp Code Code Incandescent Blank 6 LED 120 240 ø22mm - HW Series A3 – – – – – – A3-61 ...

Page 11

... HW Series Operator/Lens A3 Part Numbers: Operator/Lens Style Plastic Bezel Round Flush HW1P-1FQ0- Dome HW1P-2FQ0- Square Flush HW2P-1FQ0 place of , specify the Lens Color Code from table on previous page. 2. Operator/Lens assembly for use with standard transformers only6, not spring up terminal type. Transformer/Lamp Part Numbers: Operator/Lens ...

Page 12

... HW Series + Lens = Complete Part Voltage Part Number HW-FH20 120V AC HW-MH20 (with spring up terminals)* HW-FM40 240V AC HW-MM40 (with spring up terminals)* HW-FT80 480V AC HW-RT80 (with spring up terminals)* 110V DC** HW-RD0 (with spring up terminals)* Lens/LED Voltage Part Number Color Code Color Code 6V AC/DC ...

Page 13

... HW Series Part Numbers: Illuminated Pushbuttons Style Description Flush A3 Full Voltage 120V AC 120V AC Transformer 240V AC 240V AC Extended Full Voltage 120V AC 120V AC Transformer 240V AC 240V AC Extended with Full Shroud Full Voltage 120V AC 120V AC Transformer 240V AC 240V AC 40mm Mushroom Head Full Voltage 120V AC ...

Page 14

... HW1L-M2- HW4L-M2- Part Numbers: Transformer Contact Assemblies HW1L-A2- HW4L-A2- (lamp included) HW1L-MF2- HW4L-MF2- HW1L-AF2- HW4L-AF2- HW1L-M4- * HW4L-M4- * HW1L-A4- * HW4L-A4- * HW2L-M1- – HW2L-A1- ø22mm - HW Series = Complete Switch Style Contacts Part Number 1NO HW-FL10Q0 2NO HW-FL20Q0 1NO/1NC HW-FL11Q0 1NC HW-FL01Q0 2NC HW-FL02Q0 Style ...

Page 15

... HW Series Part Numbers: LED and Incandescent Illuminated Pushbuttons + Contact Blocks + Lead Holder + Adaptor † Transformer * Transformer not needed with full voltage types. † 2. Adaptor includes safety lever lock. Part Numbers: Lenses Style Part Number Round Flush HW1A-L1- Round Extended HW1A-L2- Ø ...

Page 16

... HW-L486 TW-T126B Exposed TW-T246B TW-T486B HW-L16D ø22mm - HW Series Part Number 1NO 1NC A3 HW-F10 HW-F01 HW-F10R HW-F01R (early make) (late break) HW-G10 HW-G01 HW-G10R HW-G01R (early make) (late break) HW-C10 HW-C01 HW-C10R HW-C01R (early make) (late break) TW-DB Part Number HW-CBL A3-67 ...

Page 17

... HW Series Part Numbers: 2–Position Selector Switches Operator Position Handle Knob 1NO Lever 1NO Knob 1NC Lever Knob 2NO Lever Part Numbers: 3–Position Selector Switches Operator Position Handle 1NO Knob 1NC Lever Knob 2NO Lever 2NO Knob 1NC 2NO Knob 2NC ...

Page 18

... For details of determining which cam to use, see page A3-79. Part Number HW-CBF10 HW-CBF01 HW-CBF11 HW-CBF20 HW-CBF02 HW-CBF22 HW-CB10 HW-CB01 HW-CB11 HW-CB20 HW-CB02 HW-CB22 ø22mm - HW Series Complete Part Plastic Bezel Metal Bezel HW1S-2T HW4S-2T HW1S-2L HW4S-2L HW1S-21T HW4S-21T HW1S-21L HW4S-21L HW1S-3T* HW4S-3T* HW1S-3L ...

Page 19

... Spring-Up HW-G10 Terminal HW-G10R Contacts (early make) Exposed HW-C10 Screw Termi- HW-C10R nal Contacts (early make) Dummy Block TW-DB 1. All assembled part numbers in catalog include standard (HW-F...) contacts. 2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex ...

Page 20

... HW K-31BF20 HW K-32CF20 HW K-33DF20 HW K-31BF22 HW K-32CF22 HW K-33DF22 ø22mm - HW Series Key retained in NO position (removable in all positions) Key retained in right position only Key retained in left position only Key retained in left and right (3 position only) Key retained in center only (3 position only) Key retained right and center (3 position only) ...

Page 21

... HW Series Contact Assembly A3 Part Numbers: Operators # of Positions 1. Operator includes two keys. 2. All standard operators are keyed alike (contact IDEC for special keys). 3. Other key removable options available. See “Other Key Removable Option Codes” on next page. Part Numbers: Contact Assemblies ...

Page 22

... See page A3-96. ø22mm - HW Series Operator = Complete Part Part Number 1NO 1NC HW-F10 HW-F01 HW-F10R HW-F01R (early make) (late break) HW-G10 HW-G01 HW-G10R HW-G01R (early make) (late break) HW-C10 HW-C01 HW-C10R HW-C01R (early make) (late break) TW-DB Appearance Part Number HW9Z-RL A3 A3-73 ...

Page 23

... Oiltight Switches & Pilot Devices Illuminated Selector Switches (Assembled) Type Part Number Maintained Full Voltage HW F-2F11Q - - X HW F-2F11H2 - 120V O Transformer 240V HW F-2F11M4 - 480V HW F-2F11T8 - Full Voltage HW F-2F20Q - - X HW F-2F20H2 - 120V X Transformer 240V HW F-2F20M4 - 480V HW F-2F20T8 - Full Voltage HW F-2F22Q - - F-2F22H2 - 120V X Transformer 240V HW F-2F22M4 - ...

Page 24

... USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Illuminated Selector Switches (Assembled) con’t Type Part Number Part Number Spring Return From Right Maintained Full Voltage HW F-3F11Q - - HW F-31F11Q - - 120V HW F-3F11H2 - HW F-31F11H2 - Transformer 240V HW F-3F11M4 - HW F-31F11M4 - 480V HW F-3F11T8 - HW F-31F11T8 - Full Voltage HW F-3F20Q - - ...

Page 25

... Type Plastic Maintained HW1F-2 HW4F-2 Spring from Right HW1F-21 HW4F-21 Maintained HW1F-3 HW4F-3 Spring from Right HW1F-31 HW4F-31 Spring from Left HW1F-32 HW4F-32 Spring from Both HW1F-33 HW4F-33 In place of , specify the Lens Color Code from table below. Code A ...

Page 26

... Units with exposed screw terminals (HW-C...) must be ordered as sub-components. ø22mm - HW Series Illuminated Operator + = Complete Part Knob Part Number 1NO 1NC HW-F10 HW-F01 HW-F10R HW-F01R (early make) (late break) HW-G10 HW-G01 HW-G10R HW-G01R (early make) (late break) HW-C10 HW-C01 HW-C10R HW-C01R (early make) (late break) TW-DB A3-77 A3 ...

Page 27

... Exposed HW-DA1B Spring Up HW-GA1 Fingersafe TW-DA1FB 1. Use with notched panel cutout to prevent unit rotation. Exposed TW-DA1B 2. Not required when using HW series nameplates See page A3-96. USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Style Voltage Part Number 120V AC TW-F126B 240V AC TW-F246B ...

Page 28

... Caution: Before putting any custom selector switch into use, it should be tested using an ohmmeter. For Operator Truth Tables, see next page. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Custom Selector Switch Building Guide 4 5 ø22mm - HW Series A3 A3-79 ...

Page 29

... A3-73 HW1S-3ST is identified by red plungers on the operator. Operator Position 2. Mounting position indicates which side of operator each Left Center Right contact should be mounted (as viewed from the front of the panel for key removable code (see page A3-73 ...

Page 30

... HW-F10R NO-(EM HW-F01R NC-(LB) R www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Operator Truth Tables con’t Operator Position Operator Position ø22mm - HW Series A3 Mounting position indicates which side of operator each contact should be mounted (as viewed from the front of the panel). A3-81 ...

Page 31

... Contact This arrangement is possible with either the HW1S-3T or HW1S-3ST operator preferred to use the HW1S-3T as this requires only the standard contacts (HW- F10 and HW-F01 and not the early make (HW-F10R) or late break (HW-F01R) contacts. Assemble as follows: www.idec.com A3-82 Oiltight Switches & Pilot Devices ...

Page 32

... X X HW-F01R mounted on left Assemble as follows: Right HW-F01 Left Knob Position HW-F10R mounted on right Assembled as follows: HW-F01 Right Left HW-F10 HW-F01 ø22mm - HW Series Operator HW1S-4T HW-F10 HW1S-4T Operator HW1S-5T HW-F01 mounted on right HW-F01 mounted on left HW-F10 mounted on right HW-F10R HW1S-5T A3 A3-83 ...

Page 33

... Flush (top) Flush (bottom) Interlock* Flush (top) Extended (bottom) 1. *Interlock type prevents both top and bottom buttons from being pressed simultaneously. 2. Clear silicon rubber cover part number HW9Z-D7D. www.idec.com A3-84 Oiltight Switches & Pilot Devices Dual Pushbutton Switches Dual Pushbutton Switches (Assembled) ...

Page 34

... Full Voltage Flush (Top) Extended (Bottom) Transformer 1. *Interlock type prevents both top and bottom buttons from being pressed simultaneously. 2. Clear silicon rubber cover part number HW9Z-D7D. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Part Numbers, con’t Top Bottom ...

Page 35

... HW Series Contact Arrangement Top Button Bottom Button A3 1NO 1NO 1NO 1NC 1NC 1NO 1NC 1NC 1NO 2NO 1NO 1NO-1NC 1NO 2NC 1NC 2NO 1NC 1NO-1NC 1NC 2NC 2NO 1NO 2NO 1NC 1NO-1NC 1NO 1NO-1NC 1NC 2NC 1NO 1. Transformers can have two or four contact blocks only. ...

Page 36

... Contact Block Mounting Position Example With Pilot Light (transformer type) www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Contact Arrangement Chart con’t Contact Block Top Button Mounting Type Normal Push Position Dummy ø22mm - HW Series Bottom Button Normal Push A3-87 A3 ...

Page 37

... HW-G10 HW-G01 HW-G10R (early make) HW-G01R (late break) HW-G10-MAU (gold contacts) HW-G01-MAU (gold contacts) HW-C10 HW-C01 HW-C10R (early make) HW-C01R (late break) TW-DB Description Terminals Part Number For use with HW-CBL on all illuminated pushbutton units. One required for each deck (pair) of contacts. ...

Page 38

... Circuit Diagrams 2 Position Up/Down Circuit Number Position Circuit Number Center Up Right No 22N9 ø22mm - HW Series No. of Part Number Positions HW1M-F1010-20 HW1M-F2020-20 HW1M-F0101-20 2 HW1M-F0202-20 HW1M-F0101-40 HW1M-F0202-40 HW1M-F1111-22N9 4 HW1M-F2222-22N9 HW1M-LF1010-20 HW1M-LF2020-20 HW1M-LF0101-20 2 HW1M-LF0202-20 HW1M-LF0101-40 HW1M-LF0202-40 HW1M-LF1111-22N9 4 HW1M-LF2222-22N9 Contact Position Mounting No. Down Center Up 1 HW-F10 X ...

Page 39

... HW1M-1010 HW1M-2020 HW1M-0101 HW1M-0202 HW1M-1111 HW1M-2222 HW1M-L1010 HW1M-L2020 HW1M-L0101 HW1M-L0202 HW1M-L1111 HW1M-L2222 Part Number 1NO 1NC HW-F10 HW-F01 HW-F10R HW-F01R (early make) (late break) HW-G10 HW-G01 HW-G10R HW-G01R (early make) (late break) HW-C10 HW-C01 HW-C10R HW-C01R (early make) (late break) TW-DB ...

Page 40

... Normal position refers to the button flush with the selector ring. 6. Depressed position refers to the button being pushed in. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Pushbutton Selectors (Assembled) Part Number 0 HW1R-2DF20 HW1R-2DF22N1 HW1R-2EF22N1 HW1R-2FF22N1 Button Color Code Color Code Black B Green G Red R Blue S White W Yellow Y Grey N ø22mm - HW Series A3 A3-91 ...

Page 41

... HW Series A3 Part Numbers: Operators Appearance Description Part Number Cam D Cam E Cam F In place of specify Button Color Code. Part Numbers: Contact Assemblies Style Contacts Standard Fingersafe Contacts 1NO 1NC 1NO/1NC 2NO 2NC 2NO/2NC Spring Up Terminal Contacts 1NO 1NC 1NO/1NC 2NO 2NC ...

Page 42

... Red Blue White Yellow Grey ø22mm - HW Series + Button = Complete Part Part Number 1NO 1NC HW-F10 HW-F01 HW-F10R HW-F01R (early make) (late break) HW-G10 HW-G01 HW-G10R HW-G01R (early make) (late break) HW-C10 HW-C01 HW-C10R HW-C01R (early make) (late break) TW-DB Code A3-93 ...

Page 43

... Contact Position Button Free Left O HW-F10 (NO) Right O Left O HW-F01 (NC) Right X Left X HW-F10R (NO-EM) Right O Left X HW-F01R (NC-LB) Right X HW Pushbutton Selector Switches - Cam N Mounting Contact Position Button Free Left O HW-F10 (NO) Right O Left O HW-F01 (NC) Right X Left X HW-F10R (NO-EM) Right O Left X HW-F01R (NC-LB) ...

Page 44

... Button Part Numbers: Rod Appearance Button Color Code Color Code Black B Green G Grey N Metal Red R Blue S White W Yellow Y HW4B-MO ø22mm - HW Series Metal Bezel HW4B-M1RS- T Button Color Code Color Code Black B HW4B-M1RS- T-ENG-R Green G Grey N Red R Blue S White W Yellow Y = Complete Part Part Number ...

Page 45

... Character height based on the number of characters and size of nameplate. Standard character size is 3/16". 3. Nameplates with standard legends are the same list price as blank nameplates. 4. Nameplates have built-in anti-rotation feature for use with notched panel cut-outs. Additional anti-rotation ring (HW9Z-RL) is not necessary. www.idec.com A3-96 Oiltight Switches & ...

Page 46

... Specify Quantity. Enter the number of nameplates desired in Qty box on the right. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Nameplates Order Form — HW Series IDEC Rep/Distributor Contact: PO number (if known): IDEC Rep/Distributor Phone: IDEC Rep/Distributor Fax & Email 7/64” 11 characters max Letter (for 7/64” ...

Page 47

... Used to prevent contact mounting lever from moving due to heavy vibration or panel maintenance. (included with all Contact Block Mounting Adaptors) 5” rod used with HW1B-M0. See Contactors Section D for more information. Provided with operator. Insert between bezel and locking ring. ...

Page 48

... USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Description/Usage HW Illuminated Unibody Replacement Lens Polycarbonate Replacement Lens Replacement LED Lamp Clear Silicon rubber cover Plastic barrier. Used when mounting the HW7 units on 30mm horizontal centers, to prevent possible interconnections between adjoining terminals. ø22mm - HW Series Part Number HWLV-LENSR ...

Page 49

... Locking Ring 50.2mm 70.2mm Square Round 30mm Monolever 0.21" (8mm) 0.90" (23mm) Pilot Lights M3.5 Terminal Screws M3.5 Terminal Screws 29.6mm www.idec.com A3-100 Oiltight Switches & Pilot Devices Dimensions — HW Series * Round: 23.6mm * Square: 24.8mm * * D1 0.5mm D2 13mm 13mm deg. 2.83" (72mm) Panel Thickness 0 ...

Page 50

... D1 23.2mm 24V AC/DC M3.5 Terminal Screws W/ Dummy Block & W/ Full Voltage Adaptor Full Voltage Adaptor M3.5 Terminal Screws W/ Transformer ø22mm - HW Series 2.36" (60mm) 1.33" (34mm) Extended with Full Shroud Mushroom 29mm 18.5mm Extended D1 Mushroom 40mm 18.5mm Square D1 = 0.51" 13mm ...

Page 51

... HW Series Unibody Illuminated A3 Panel Thickness 0.8mm to 6.0mm Gasket Locking Ring M3.5 Terminal Screws 60mm 11.5mm 63mm Selector Switches Illuminated Selector Switches Gasket Panel thickness: 0.8mm to 6.0mm Locking Ring 21mm 2 blocks 89.5mm 4 blocks 109.5mm Key Switches D1 = 13mm www.idec.com A3-102 Oiltight Switches & Pilot Devices Dimensions con’ ...

Page 52

... The depth of 3-contact type depends on the combination of contact blocks at top and bottom pushbuttons. Top Button Bottom Button Depth (Note) • Transformer (480V) Transformer, DC-DC Converter 89.5 (2 contacts), 109.5 (4 contacts) ø22mm - HW Series With Button Markings (I/ON and O/OFF) ON OFF 29.8 1 contact block 2 contact blocks 2 contact blocks 1 contact block 89 ...

Page 53

... HW Series Jumbo Dome Pilot Lights Dimensions Panel Thickness M3.5 Terminal Screw Locking Ring Rubber Gasket 0.5 34.4 50.5 LW9Z-BM Metallic Mounting Hole Plug ø 25.8mm Gasket Lock Nut HW9Z-D7D Dual Pushbutton Rubber Cover 22.5 33 HW9Z-KL1 Padlock Cover 82.5mm 30mm 24mm 29 ...

Page 54

... Utilization categories AC-15 and DC-13. Operation rate: 1,800 op. hour Load factor: 0.4 0.05 ± www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Accessory Dimensions con’t HW9Z-KG2-TK2120 TOP Marking Operator Specification Charts — HW Series DC Voltages 48 110 4 2 1.1 AC Voltages ø ...

Page 55

... IDEC strongly recommends using the safety lever lock (HW9Z-LS, yellow) to prevent heavy vibration or maintenance personnel from unlocking the con- tact assembly series can be mounted vertically with a minimum spacing but spacing should be determined to ensure easy operation (recommended minimum spacing: 100 mm). 2. Mount the control unit onto the panel, lock the lever, and push in the safety lever lock to install ...

Page 56

... Installing the Rubber Cover When using the HW7D pushbuttons in places where the pushbuttons are subjected to water splash or an excessive amount of dust, make sure to use the HW9Z-D7D rubber boot (IP65) which is ordered sepa- rately. Notes for Installing the Rubber Cover 30 30 Remove the gasket from the operator, and install the rubber boot on the operator ...