FILAMENT LAMP

10-1119.1199

Manufacturer Part Number
10-1119.1199
Description
FILAMENT LAMP
Manufacturer
EAO
Datasheet

Specifications of 10-1119.1199

Supply Voltage
48V
Current Rating
25mA
For Use With
SWISSTAC Series Switches
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Technical Data
Environmental conditions
>
Switching system
Material
Mechanical characteristics
Emergency-stop pushbutton foolproof
Rated Insulation Voltage U
250 V, as per EN IEC 60947-1
Electrical life
8000 cycles of operation at 250 VAC, 1 A
Conventional free air thermal current I
5 A, as per EN IEC 60947-5-1
Switch rating
Switch rating AC with silver contact (gold plated),
250 VAC, 1 A, service category AC-15, as per EN IEC 60947-5-1
Short-circuit protection
Series-connected blow-out fuse 5 A gL
Storage temperature
-40 °C ... +85 °C, as per EN IEC 60068
Operating temperature
-25 °C ... +55 °C, as per EN IEC 60068-2
Self cleaning, double-break slow-make element with four-path
contacts (contact opening width 2 x 1.5 mm). The slow-make
elements are constructed as per EN IEC 60947-5-1.
Mushroom-head cap
Polyamide (PA)
Actuator housing
Polyetherimide (PEI), self-extinguishing
Switching element
Polyamide (PA), Polysulfon (PSU)
Material of contact
Silver (Ag)
Terminals
Soldering terminal
max. wire-cross section 2 x 1.0 mm²
max. wire-cross section of stranded cable 1 x 0.75 mm²
also pluggable 2.8 x 0.5 mm
Actuating force
max. 65 N (measured on mushroom-head cap)
Unlock torque
15 Ncm
Actuating travel
10 mm
Rebound time
≤2 ms
Mechanical lifetime
50 000 cycles of operations
i
th
Electrical characteristics
0
0
0
0
Environmental conditions
Rated Operational Voltage U
250 VAC, as per EN IEC 60947-1
Rated Insulation Voltage U
300 VAC, as per EN IEC 60947-5-1
Contact resistance
New state ≤50 mΩ, as per DIN IEC 60512-2-5
Electrical life
6050 cycles of operation
Conventional free air thermal current I
5 A, as per EN IEC 60947-5-1
the maximum current in continuous operation and at ambient
temperature must not exceed the quoted maximum values.
Switch rating
Switch rating AC (inductive) with silver contact (gold plated), service
category AC-13, as per EN IEC 60947-5-1
Voltage
Current
Switch rating AC (inductive) with silver contact (gold plated), service
category AC-14, as per EN IEC 60947-5-1
Current
Voltage
Switch rating (non-inductive) with silver contact (gold-plated)
Voltage
Current
Switch rating DC with silver contact (gold plated), service category
DC-13, as per EN IEC 60947-5-1
Voltage
Current
Recommended minimum operational data
Silver contact (Soldering terminal) 20 VAC, 10 mA
Electric strength
4000 VAC, 50 Hz, 1 min., as per DIN IEC 60512-2
between all terminals and earth
Short-circuit protection
Series-connected blow-out fuse 10 A gL
Overvoltage category
III, as per EN IEC 60947-5-1
Degree of pollution
3, as per EN IEC 60947-1
Storage temperature
-40 °C ... +85 °C, as per EN IEC 60068
Operating temperature
-25 °C ... +55 °C, as per EN IEC 60068-2
Shock resistance
(single impacts, semi-sinusoidal)
500 m/s²puls width 11 ms, as per EN IEC 60068-2-27
24 VAC
6 A
24 VAC
5 A
24 VDC
6.0 A
24 VDC
2.0 A
60 VAC
6 A
60 VAC
4 A
60 VDC
2.0 A
60 VDC
1.0 A
i
e
120 VAC
5 A
120 VAC
3 A
110 VDC
0.7 A
110 VDC
0.4 A
Swisstac
th
250 VAC
3 A
250 VAC
2 A
240 VDC
0.5 A
240 VDC
0.2 A
02.2009