HMC1021Z-RC Honeywell Microelectronics & Precision Sensors, HMC1021Z-RC Datasheet
HMC1021Z-RC
Specifications of HMC1021Z-RC
HMC1021Z-RC
Related parts for HMC1021Z-RC
HMC1021Z-RC Summary of contents
Page 1
Magnetic Sensors HMC1001/1002/1021/1022 The Honeywell HMC100x and magnetic sensors are one and two-axis surface mount sensors designed for low field magnetic sensing. By adding supporting signal processing, cost effective magnetometers or compassing solutions are enabled. Th ese ...
Page 2
HMC1001/1002/1021/1022 HMC1001/1002 SPECIFICATIONS Characteristics Bridge Elements Supply Resistance Operating Temperature Storage Temperature Field Range Full scale (FS) – total applied field Linearity Error Hysteresis Error Repeatability Error S/R Repeatability Output variation after alternate S/R pulses Bridge Offset Field = 0 ...
Page 3
HMC1001/1002/1021/1022 HMC1021/1022 SPECIFICATIONS Characteristics Bridge Elements Supply Resistance Operating Temperature Storage Temperature Field Range Full scale (FS) – total applied field Linearity Error Hysteresis Error Repeatability Error Bridge Offset Field = 0 gauss after Set pulse Sensitivity ...
Page 4
HMC1001/1002/1021/1022 KEY PERFORMANCE DATA 4 www.honeywell.com ...
Page 5
HMC1001/1002/1021/1022 PACKAGE / PINOUT SPECIFICATIONS Arrow indicates direction of applied field that generates a positive output voltage after a SET pulse. BASIC DEVICE OPERATION The Honeywell HMC100x and HMC102x Anisotropic Magneto-Resistive (AMR) sensors are simple resistive Wheatstone bridges to measure ...
Page 6
HMC1001/1002/1021/1022 These resistive elements are aligned together to have a common sensitive axis (indicated by arrows on the pinouts) that will provide positive voltage change with magnetic fields increasing in the sensitive direction. Because the output only is in proportion ...
Page 7
HMC1001/1002/1021/1022 For simpler circuits with less critical requirements for noise and accuracy, a single polarity pulse circuit may be employed periodically (all sets or all resets). With these uni-polar pulses, several uni-polar pulses become close in performance to a single ...
Page 8
HMC1001/1002/1021/1022 SET/RESET STRAP OPERATION The reasons to perform a set or reset on an AMR sensor are recover from a strong external magnetic field that likely has re-magnetized the sensor optimize the magnetic domains for most ...
Page 9
HMC1001/1002/1021/1022 The next circuit implementation is the classic set/reset design in which a push-pull output stage (totem pole stage) drives one end of the HMC1001 set/reset strap, with the other end grounded. Figure 3 shows this circuit. Vsource Vsource The ...
Page 10
HMC1001/1002/1021/1022 1000 7 Vset D1 1N4148 Figure 4 – Higher Voltage Set/Reset Circuit for HMC1001 & HMC1002 The three strap resistances are chosen at 1.8 ohms, or the worst-case high resistance points. Since they require a minimum ...
Page 11
HMC1001/1002/1021/1022 APPLICATION CIRCUITS The following are typical application circuits using the HMC100x and HMC102x sensors. TWO AXIS COMPASS OR MAGNETOMETER Figure 5 shows the typical schematic diagram. VDD VDD 850 850 850 850 ...
Page 12
... 3-axis compass designed with the HMC102x series sensor, parts like the HMC1022 plus the HMC1021Z can be used, with replication of the difference amplifier stages for each axis. By choosing the 1 Meg-ohm and 4.99k-ohm resistors, the gain with a 5 volt supply produces about a 1V/gauss transfer characteristic and centered at half supply (2 ...
Page 13
HMC1001/1002/1021/1022 R1 R1 1.1K 1. 1.1K 1.1K HMC1021 HMC1021 R12 R12 4.5 4.5 MOUNTING CONSIDERATIONS Stencil Design and Solder Paste A 4 mil stencil and 100% paste coverage is recommended for the electrical contact pads. Pick ...
Page 14
HMC1001/1002/1021/1022 PACKAGE OUTLINES 14 www.honeywell.com ...
Page 15
... Two Axis Magnetic Sensor, 20-pin SOIC HMC1002-TR HMC1021S One Axis Magnetic Sensor, 8-pin SOIC HMC1021S-TR HMC1021Z One Axis Magnetic Sensor, 8-pin SIP HMC1022 Two Axis Magnetic Sensor, 16-pin SOIC HMC1022-TR * When ordering the –RC in the product part number represents RoHS compliant. This labeling is temporary during the transition period from leaded to non-leaded parts ...