AS5055-EQFT austriamicrosystems, AS5055-EQFT Datasheet - Page 12

no-image

AS5055-EQFT

Manufacturer Part Number
AS5055-EQFT
Description
IC ENCODER ROTARY 16-QFN
Manufacturer
austriamicrosystems
Type
Linear, Rotary Encoder - Programmabler
Datasheet

Specifications of AS5055-EQFT

Sensing Range
30mT ~ 80mT
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
8.5mA
Output Type
Digital
Features
Low Power
Operating Temperature
-20°C ~ 85°C
Package / Case
16-VQFN Exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Output (max)
-
Other names
AS5055-EQFTCT
AS5055
Data Sheet – SPI Communication
10.5.3 CLEAR ERROR FLAG Command
The CLEAR ERROR FLAG command is implemented as READ command. This command clears the ERROR FLAG
which is contained in every READ frame. The READ data are 0x0000, which indicates a successful clear command.
Figure 7. CLEAR ERROR FLAG Command
The package necessary to perform a CLEAR ERROR FLAG is built up as follows.
Possible conditions which force the ERROR FLAG to be set:
Note: If the error flag is set to high because of a communication problem the flag remains set until it will be cleared by
an external command.
www.austriamicrosystems.com
Bit
MSB
wrong parity
wrong command
wrong number of clocks (no full transmission cycle or too many clocks)
1
14
1
13
1
12
0
11
0
CLEAR ERROR FLAG Command
CLEAR ERROR FLAG command
10
1
9
1
Revision 1.2
8
1
7
0
6
0
5
0
4
0
3
0
2
0
1
0
12 – 22
LSB
PAR
PAR

Related parts for AS5055-EQFT