IC COMPASS 3 AXIS I2C 16LCC SMD

HMC5883L-TR

Manufacturer Part Number
HMC5883L-TR
Description
IC COMPASS 3 AXIS I2C 16LCC SMD
Manufacturer
Honeywell Microelectronics & Precision Sensors
Series
HMCr
Type
Compass - Three Axisr
Datasheets

Specifications of HMC5883L-TR

Sensing Range
±8G
Voltage - Supply
2.16 V ~ 3.6 V
Current - Supply
100µA
Output Type
Differential Voltage
Features
Compass - Three Axis
Operating Temperature
-30°C ~ 85°C
Package / Case
16-LCC
Measuring Range
-8G To +8G
Resolution
5 MG
Supply Voltage Range
1.71V To 3.7V, 2.16V To 3.6V
No. Of Axes
3
Sensor Case Style
LCC
Ic Interface Type
I2C
Supply Voltage Max
3.6V
No. Of Pins
16
Resoluti
5 MG
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Output (max)
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
342-1082-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HMC5883L-TR
Manufacturer:
NSC
Quantity:
1 043
Part Number:
HMC5883L-TR
Manufacturer:
HONEYWELL
Quantity:
20 000
HMC5883L
Configuration Register A
The configuration register is used to configure the device for setting the data output rate and measurement configuration.
CRA0 through CRA7 indicate bit locations, with CRA denoting the bits that are in the configuration register. CRA7 denotes
the first bit of the data stream. The number in parenthesis indicates the default value of that bit.
The Table below shows all selectable output rates in continuous measurement mode. All three channels shall be
measured within a given output rate. Other output rates with maximum rate of 160 Hz can be achieved by monitoring
DRDY interrupt pin in single measurement mode.
www.honeywell.com
CRA7
(1)
Location
CRA7
CRA6 to CRA5
CRA4 to CRA2
CRA1 to CRA0
DO2
0
0
0
0
1
1
1
1
MS1
0
0
1
1
DO1
0
0
1
1
0
0
1
1
0
1
0
1
MS0
CRA6
MA1(1)
DO0
0
1
0
1
0
1
0
1
Measurement Mode
Normal measurement configuration (Default). In normal measurement
configuration the device follows normal measurement flow. The positive and
negative pins of the resistive load are left floating and high impedance.
Positive bias configuration for X, Y, and Z axes. In this configuration, a positive
current is forced across the resistive load for all three axes.
Negative bias configuration for X, Y and Z axes. In this configuration, a negative
current is forced across the resistive load for all three axes..
This configuration is reserved.
Name
CRA7
MA1 to MA0
DO2 to DO0
MS1 to MS0
Table 4: Configuration Register A Bit Designations
Typical Data Output Rate (Hz)
0.75
1.5
3
7.5
15 (Default)
30
75
Not used
CRA5
MA0(1)
Table 3: Configuration Register A
Table 6: Measurement Modes
Table 5: Data Output Rates
Description
This bit must be cleared for correct operation.
Select number of samples averaged (1 to 8) per
measurement output.
00 = 1; 01 = 2; 10 = 4; 11 = 8 (Default)
Data Output Rate Bits. These bits set the rate at which data
is written to all three data output registers.
Measurement Configuration Bits. These bits define the
measurement flow of the device, specifically whether or not
to incorporate an applied bias into the measurement.
CRA4
DO2 (1)
CRA3
DO1 (0)
CRA2
DO0 (0)
CRA1
MS1 (0)
CRA0
MS0 (0)