AS5043-ASSU austriamicrosystems, AS5043-ASSU Datasheet - Page 14

no-image

AS5043-ASSU

Manufacturer Part Number
AS5043-ASSU
Description
IC ENCODER PROG 10-BIT 16-SSOP
Manufacturer
austriamicrosystems
Type
Linear, Rotary Encoder - Programmabler
Datasheet

Specifications of AS5043-ASSU

Sensing Range
45mT ~ 75mT
Voltage - Supply
3 V ~ 3.6 V, 4.5 V ~ 5.5 V
Current - Supply
21mA
Current - Output (max)
4mA
Output Type
Analog, Digital
Features
Programmable
Operating Temperature
-40°C ~ 125°C
Package / Case
16-SSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AS5043-ASSU
Manufacturer:
AMS
Quantity:
101
AS5043
Data Sheet – Programming the AS5043
Figure 13: Zero Position Programming (shown for 360° mode)
12.2 Analog Mode Programming
The analog output can be configured in many ways:
It consists of three major building blocks,
In the default configuration (all OTP bits = 0), the analog output is set for 360° operation, internal DAC reference
(VDD5V/2), external OPAMP gain, 0-100% ratiometric to VDD5V.
Shown below is a typical example for a 0°-360° range, 0-5V output. The complete application requires only one external
component, a buffer capacitor at VDD3V3 and has only 3 connections VDD, VSS and Vout (connectors 1-3).
Note: the default setting for the OPAMP feedback path is:FB_intEn=0=external. The external resistors Rf and Rg must be
installed. In the programmed state (FB_intEn=1=internal), these resistors do not need to be installed as the feedback
path is internal (Rf_int and Rg_int).
www.austriamicrosystems.com
a digital range preselector,
a 10-bit Digital-to-Analog-Converter (DAC)
and an OP-AMP buffer stage.
voltage
analog
output
2V
5V
0V
VDD5V
90°
the output can be electrically rotated to
match a given output voltage to any
mechanical position
Revision 1.80
180°
270°
360°
Mechanical
angle
14 – 36