VCNL4000-GS08 Vishay, VCNL4000-GS08 Datasheet - Page 10

no-image

VCNL4000-GS08

Manufacturer Part Number
VCNL4000-GS08
Description
IC OPTICAL SENSOR I2C 12-LLP
Manufacturer
Vishay
Series
VCNL4000r
Type
Short distance Proximity/Ambient Light Sensorr
Datasheet

Specifications of VCNL4000-GS08

Output Type
Digital - I²C
Sensor Type
Light and Proximity
Sensing Range
1mm To 200mm
Output Current
1.5µA
Sensor Output
I2C
Supply Voltage Range Dc
2V To 3.6V
Maximum Operating Temperature
+ 85 C
Supply Voltage
3.6 V
Operating Supply Voltage
3.6 V
Mounting Style
SMD/SMT
Sensing Distance
1 mm to 200 mm
Minimum Operating Temperature
- 25 C
Features
Integrated module with ambient light sensor, proximity sensor, signal conditioning IC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
751-1505-2
VCNL4000
Vishay Semiconductors
3.3 Continuous Conversion Mode in Ambient Light Measurement
In the following is a detail description of the function “continuous conversion” (bit 7 of register #4)
Standard mode (bit 7 of reg #4 = 0):
In standard mode the ambient light measurement is done during a fixed time frame of 100 ms. The single measurement itself
takes actually only appr. 300 μs.
The following figures show examples of this measurement timing in standard mode using averaging function 2 and 8 as
examples for illustration (possible values up to 128).
Note
•  Independent of setting of averaging the result is available only after 100 ms.
Continuous conversion mode (bit7 of reg #4 = 1):
In continuous conversion mode the single measurements are done directly subsequent after each other.
See following examples in figure 17 and 18
www.vishay.com
10
THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
Final Measurement Result = Average of these 2 Measurements
22315
460 μs
Fig. 15 - Ambient Light Measurement with Averaging = 2;
Fig. 17 - Ambient Light Measurement with Averaging = 2;
Start
Start
1.5 ms
using Continuous Conversion Mode
50 ms
100 ms
For technical questions, contact:
Fully Integrated Proximity and Ambient Light Sensor
This document is subject to change without notice.
with Infrared Emitter and I
22317
sensorstechsupport@vishay.com
Final Measurement Result = Average of these 8 Measurements
22316
460 μs
Fig. 16 - Ambient Light Measurement with Averaging = 8;
Fig. 18 - Ambient Light Measurement with Averaging = 8;
22318
Start
Start
using Continuous Conversion Mode
2
12.5 ms
C Interface
4.2 ms
100 ms
www.vishay.com/doc?91000
Document Number: 83798
Rev. 1.3, 06-Apr-11

Related parts for VCNL4000-GS08