02110102-000 Measurement Specialties Inc/Schaevitz, 02110102-000 Datasheet

SNSR TILT RATIO 60DEG 500MA FLNG

02110102-000

Manufacturer Part Number
02110102-000
Description
SNSR TILT RATIO 60DEG 500MA FLNG
Manufacturer
Measurement Specialties Inc/Schaevitz
Series
AccuStar®r
Datasheet

Specifications of 02110102-000

Rohs Status
RoHS non-compliant
Operating Angle
±60°
Output Type
Ratiometric
Mounting Type
Flange, Horizontal
Voltage - Supply
5 V ~ 15 V
Current - Output
500mA
Package / Case
2.595" L x 2.030" W x 1.2" H (65.913mm x 49.555mm x 30.48mm)
Other names
356-1033
Position Sensors Technical
Support:
Tel: 757-766-4348
Fax: 757-766-4297
Email: position@meas-spec.com
Single Axis ±60° Range
DESCRIPTION
The AccuStar
extremely accurate angle measurement device.
This compact and rugged sensor is ideal where
space is critical and environmental conditions are
serious design concerns.
capacitance-based sensor with no moving parts.
When rotated about its sensitive axis, this unique
sensor provides an exceedingly linear variation in
capacitance, which is electronically converted into
angular data. The sensor and low-power CMOS
electronics are encased in a rugged plastic housing
ready to install as a system component or as a
stand-alone device.
analog, ratiometric, digital or serial models, the
clinometer produces an output signal
corresponding to direction and magnitude of
angular displacement.
AccuStar
The heart of the system is a patented,
Designed for easy integration, with a choice of
FEATURES
APPLICATIONS
CE certified
Just 2" in diameter
Rugged plastic housing
Extremely accurate
Weighs only 2 oz.
Wheel alignment
Construction equipment
Antenna positioning
Robotics
Measurement Specialties, Inc.
®
Electronic Clinometer
G
1000 Lucas Way Hampton, VA 23666 USA
®
Electronic Clinometer
is an
- 1 -
G
www.meas-spec.com
Total Range
Linear Range
Threshold
Linearity
Null to 10°
10 to 45°
45 to 60°
Null Repeatability
Cross Axis Error
Time Constant
Freq. Response (-3db)
RF Susceptibility
G
p e r f o r m a n c e s p e c i f i c a t i o n s
757-766-1500
G
800-745-8008
G
±60°
0.001°
±1%
Monotonic
0.05°
<1% up to 45°
0.3 sec
0.5 Hz
<±2°
Fax 757-766-4297
±45°
±0.1°

Related parts for 02110102-000

02110102-000 Summary of contents

Page 1

AccuStar Single Axis ±60° Range DESCRIPTION The AccuStar Electronic Clinometer ® extremely accurate angle measurement device. This compact and rugged sensor is ideal where space is critical and environmental conditions are serious design concerns. The heart of the system is ...

Page 2

... The assembled sensor is half filled with a dielectric liquid and inert gas. Rotation of the sensor produces a linear change in capacitance resulting in a corresponding output signal Model Number Description Ratiometric 02110002-000 Vertical Flange 02110102-000 Horizontal Flange Analog 02111002-000 Vertical Flange 02111102-000 Horizontal Flange Digital ...

Page 3

AccuStar ® Electronic Clinometer Ratiometric Output The Ratiometric clinometer is a signal conditioned sensor that has been designed to operate like a potentiometer. This is a three wire device: power; power ground; and signal. The signal is referenced to power ...

Page 4

AccuStar ® Electronic Clinometer Analog Output The Analog clinometer is a signal conditioned sensor which has been designed for dc voltage, bipolar operation. The clinometer requires a bipolar supply of ±8 to ±15 VDC and delivers an output of ±3.6 ...

Page 5

... Electronic Clinometer Serial Data Output The Serial clinometer is a signal conditioned sensor which resolves the angle of tilt to 16 bits of information plus a polarity bit. This device was designed to transmit data to a microcontroller I/O card through a three wire interface which will work at both TTL and CMOS logic levels. ...

Page 6

... Electronic Clinometer Digital Pulse Width Output The Digital Pulse Width clinometer is a signal conditioned sensor which resolves the angle of tilt to pulses, the length of which are directly proportional to the angle. When a trigger pulse is received on trigger 1 or trigger 2 a pulse is sent out the corresponding PW1 or PW2 line ...

Related keywords