TO-1-102/EZ MOELLER, TO-1-102/EZ Datasheet

CAM SWITCH, ON-OFF

TO-1-102/EZ

Manufacturer Part Number
TO-1-102/EZ
Description
CAM SWITCH, ON-OFF
Manufacturer
MOELLER
Datasheet

Specifications of TO-1-102/EZ

No. Of Poles
2
No. Of Switch Positions
2
Contact Current Ac Max
20A
Svhc
No SVHC (18-Jun-2010)
Angle
90°
External Depth
35mm
External Length / Height
48mm
External Width
48mm
Ip/nema Rating
IP55
Indexing
RoHS Compliant
Type: T0−1−102/EZ
Article No.: 091082
Sales text ON−OFF−SWITCH
Contact sequence
1
Ordering information
Design
Description
Main conducting paths
Auxiliary contacts
Max. motor rating
Rated uninterrupted current
General
Standards
No. of poles
N/O = normally open contact
N/C = normally closed contact
AC−23A 400/415 V 50−60 Hz
P
I
u
N/O
kW
M
B
A
Centre mounting
Without auxiliary contacts
2
0
0
6.5
20
IEC/EN 60947, VDE 0660,
IEC/EN 60204, CSA, UL
Switch−disconnectors to
IEC/EN 60947−3
Load−break switches to
IEC/EN 60947−3

Related parts for TO-1-102/EZ

TO-1-102/EZ Summary of contents

Page 1

... Sales text ON−OFF−SWITCH Ordering information Design Description Main conducting paths No. of poles Auxiliary contacts N/O = normally open contact N/C = normally closed contact Max. motor rating AC−23A 400/415 V 50−60 Hz Rated uninterrupted current Contact sequence General Standards 1 Centre mounting Without auxiliary contacts ...

Page 2

... Load rating with intermittent operation, class Short−circuit rating Fuse Rated short−time withstand current (1 s current) Safe isolation to VDE 0106 Part 101 and Part 101/A1 between the contacts Switching angles Contact units Double−break contacts Current heat loss per contact ...

Page 3

... Rated breaking capacity, motor load switch cos = 0.35 230 V 400 V 500 V 690 V Rated operational current 440 V load−break switch AC−21A AC−3 motor load switch motor rating 230 V 230 V Star−delta 400 V 400 V Star−delta 500 V 500 V Star−delta 690 V 690 V Star−delta AC− ...

Page 4

... Voltage per contact pair in series DC−21A Rated operational current 240 V 240 V Contacts DC−23A, motor load switch L Rated operational current Contacts 48 V Rated operational current Contacts 60 V Rated operational current Contacts 120 V Rated operational current Contacts 240 V Rated operational current Contacts DC−13, Control switches L/R = ...

Page 5

... Dimensions not included Depth of a contact unit: 9.5 mm Dimensions 5 difference admissible between 2 conductors T5(B)−...: Maximum of 1 cross−section size difference admissible between 2 conductors For type T8−3−8342/... the following applies: switching angle = 90° and flat connection = 1 busbar 25 × busbars 20 × 3 ...

Page 6

T0−1−.../EZ "Y T0−1−.../E + EZ−T0 + S−(SOND−)T0 Dimensions Characteristic curve 6 ...

Page 7

... For utilisation category AC−4 (extreme load: 100 % inching, reversing or plugging) The blocked rotor current of the motor should not exceed the rated current of the switch for AC−21A to ensure a reasonable device lifespan. Moeller GmbH, Hein−Moeller−Str. 7−11, D−53115 Bonn E−Mail: catalog@moeller.net, Internet: www.moeller.net, http://catalog.moeller.net HPL− ...

Related keywords