GV2AF3 SQUARE D, GV2AF3 Datasheet - Page 38

no-image

GV2AF3

Manufacturer Part Number
GV2AF3
Description
MANUAL STARTER COMBO BLOCK 600VAC 38A
Manufacturer
SQUARE D
Datasheet

Specifications of GV2AF3

Rohs Compliant
YES
Current Rating
38A
Accessory Type
Combo Block
Voltage Rating
600VAC
Wiring, Communications,
and Busbar System
18-38
APP2R4H1
APP2D1•
LAD35
LAD33
LAD3B
Table 18.144: Splitter Boxes
A total of up to eight starters is permissible after extensions. Use multiple quantities of the same catalog number to
create the desired line-up.
Table 18.145: Power Connection Components for One Starter
Table 18.146: Power Connection Accessories for One Starter
Table 18.147: Control Connection Module for One Starter
Table 18.148: Spare or Replacement Parts
50 A power splitter box
50 A power and control splitter box
Assembly and power connection kit
Reversing kit b
Upstream terminal block (50 A max)
Downstream terminal block (50 A max)
Control connection module
(integrating contact block GVAE20)
Plate for mounting a GV2ME manual starter
Power connection module
Control-command splitter box (single, for
mounting on a power splitter box)
Replacement electromechanical relay (for control connection module)
a
b
c
d
e
Connection to an APP1C
To create a TeSys D reverser, use two LC1D contactors, one assembly and power connection kit, and one reversing kit.
Relay supplied mounted on the front panel of the control connection.
The use of TeSys D low consumption contactors is recommended.
Connection to an APP1C
TeSys
Description
Description
Description
Description
Description
®
Contactors and Motor Protectors with Spring Terminals
•••
•••
module via APP2CX adaptor (LAD35).
module via APP2CX adaptor (LAD35).
1 x HE10 8I/8O
1 x HE10 16I and 1 x HE10 8O
Per module APP1C
AS-Interface
One LAD31 plate for GV2ME and two LAD34 power connection modules
One set of bus bars and one mechanical interlock
1 x HE10 8I/8O
1 x HE10 16I and 1 x HE10 8O
Via module APP1C
AS-i
Type of Control-command
Max. Connection
I11
16 mm
6 mm
Cross-Section
Connection on Control
12–240 Vac or
Type of Control-command
Coil Voltage
24–125 Vdc
24–48 Vdc
Control System Side
D-Line
2
System Side
2
(10 AWG)
Discount
Schedule
Connection on
(6 AWG)
•••
•••
Electromechanical c
Without relay d
e
a
Power supply for one or two power splitter boxes
Connection of motor cables
Type of Coil Control
Kit Consists of:
Relay
per Starter
No. of I/O
1I/1O
2I/1O
2I/1O
1I/1O
No. of I/O per
Refer to Catalog 8502CT0101
Starter
1I/1O
2I/1O
2I/1O
1I/1O
Use
Starters
No. of
Type of Starter
1
1
1
4
4
2
4
2
4
1
Non-reversing
Non-reversing
Reversing
Reversing
No. of Starters
per Unit
Sold in
Lots of
2
4
4
4
2
4
2
4
10
10
10
10
1
1
1
1
1
1
Catalog Number
Catalog Number
Catalog Number
Catalog Number
Catalog Number
APP2R4H1
APP2R4H2
APP2R2AS
APP2R4AS
APP2R4H3
APP2R4H4
APP2D1D
APP2D2D
APP2R2E
APP2R4E
APP2R2C
APP2R4C
APP2R2A
APP2R4A
LAD351
APP2D1
APP2D2
APP2ER
LAD331
LAD322
LAD324
LAD311
LAD341
LAD32
LAD3B
LAD31
www.schneider-electric.us
© 2009 Schneider Electric
All Rights Reserved
$ Price
$ Price
$ Price
$ Price
$ Price
124.00
124.00
124.00
124.00
124.00
124.00
52.00
93.00
21.00
20.70
83.00
41.40
72.00
31.10
31.10
12.30
11.30
11.30
11.30
11.30
11.30
11.30
5.00
6.20
7.50
7.50

Related parts for GV2AF3