50.12.9.012.1000 FINDER, 50.12.9.012.1000 Datasheet

RELAY, PCB, SAFETY, 8A, 12V

50.12.9.012.1000

Manufacturer Part Number
50.12.9.012.1000
Description
RELAY, PCB, SAFETY, 8A, 12V
Manufacturer
FINDER
Datasheet

Specifications of 50.12.9.012.1000

Coil Voltage Vdc Nom
12V
Coil Resistance
205ohm
Contact Current Max
15A
Contact Voltage Ac Nom
250V
No. Of Poles
2
Relay Mounting
PC Board
External Width
29mm
External Depth
12.4mm
Svhc
No SVHC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
PCB Relay with forcibly guided contacts
according to EN 50205 type B
2 CO contacts *
*According to EN 50205 only 1 NO and 1 NC
F
S
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated voltage/Maximum switching voltage V AC
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220 V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts
Ambient temperature range
Environmental protection
Approvals (according to type)
(11-14 and 21-22 or 11-12 and 21-24) shall be
OR
High physical separation between adjacent
contacts
Cadmium Free contact materials
8 mm, 6 kV (1.2/50 µs) isolation, coil-contacts
Flux proof: RT II
EE
“General technical information” page V
UL H
ORSEPOWER AND
used as forcibly guided contacts.
0.4
29
N
)
P
ILOT
D
V AC (50/60 Hz)
UTY RATINGS
VA (50 Hz)/W
12.4
mW (V/mA)
AC (50 Hz)
1
AC/DC
AC/DC
cycles
cycles
V DC
V AC
kW
DC
VA
VA
ms
°C
A
A
5 - 6 - 12 - 24 - 48 - 60 - 110 - 125
2 Pole 8 A
5 mm pinning
PCB mounting
Copper side view
(0.75…1.2)U
2 CO (DPDT)
8/0.65/0.2
—/10 · 10
—/0.4 U
—/0.1 U
300 (5/5)
–40…+70
250/400
100 · 10
6 (8 mm)
50.12
—/0.7
2,000
1,500
8/15
AgNi
10/4
0.37
500
RT II
N
N
3
6
N
50 Series - Safety relay 8 A
1

Related parts for 50.12.9.012.1000

50.12.9.012.1000 Summary of contents

Page 1

Features PCB Relay with forcibly guided contacts according to EN 50205 type contacts * High physical separation between adjacent • contacts Cadmium Free contact materials • (1.2/50 µs) isolation, coil-contacts • Flux proof: ...

Page 2

Ordering information Example: 50 series safety relay (DPDT contacts coil Series Type 1 = PCB - 5 mm pinning No. of poles pole 8 A ...

Page 3

Contact specification Electrical life (AC) v contact current Resistive load - cosϕ Inductive load - cosϕ = 0.4 Alternative selection of NO and NC contacts to provide Forcibly guided (mechanically linked) contacts, in accordance with ...

Page 4

...

Related keywords