ACTUATOR

CES-A-BBA

Manufacturer Part Number
CES-A-BBA
Description
ACTUATOR
Manufacturer
EUCHNER
Datasheet

Specifications of CES-A-BBA

External Depth
40.5mm
External Length / Height
131mm
Operating Temperature Max
55°C
Operating Temperature Min
-0°C
Non-Contact Safety Switches CES/CEM
Safety Switch CES-A-S5H-01
Dimension drawing
Safety precautions
To ensure safety, both safety outputs (LA and LB) must always be evaluated.
Typical operating distance (for safety actuator and position actuator)
For a side approach direction for the actuator and safety switch, a minimum distance of s = 3 mm
must be maintained so that the operating distance of the side lobes is not entered.
32
Safety and identification functions
Read head and evaluation unit integrated in the standard housing
Semiconductor output
Connection using 12-pin plug connector (Plug connector see page 66)
In combination with safety actuator CES-A-BBA and position
actuator CES-A-NBA-.
-30
-25
Secondary
beam
N
40,5
-20
40
OFF
16,5
12,5
-15
-10
LED status
indication
LED
indicator
Dog number
Centre offset m [mm]
s
ON
-5
Actuator
25
20
15
10
5
Read
m
head
0
Switch-on
distance S
Switch-off
distance
-5
-10
a0
Hysteresis
D3 D2 D1 D0
M
30
-15
23
ON
OFF
Output state
±0,1
x1
Subject to technical modifications; no responsibility is accepted for the accuracy of this information.
OFF
Active face
Secondary
-20
beam
N
-25
S
a0
-30
Hysteresis
Distance s
Switching characteristics
2 safety outputs (semiconductor outputs)
4 data outputs for actuator number (semiconduc-
tor outputs, not safety output)
Notes on the electrical connection
Changing the approach direction
The active face of the read head can be adjusted
in 5 directions. The face is marked with the
EUCHNER logo. The center of the circle
corresponds to the middle of the read head.
24 V
24 V
24 V
24 V
Read head
+LA
+LB
(actuator detected)
The operating voltage U
protected.
The data outputs D0, D1, D2, D3 have no
safety function.
Both safety outputs LA and LB must be
evaluated.
The safety outputs LA and LB as well as the
data outputs D0, D1, D2, D3 are short
circuit-proof.
All the electrical connections must either be
isolated from the mains supply by a safety
transformer according to IEC/EN 61558
with limited output voltage in the event of a
fault, or by other equivalent isolation
measures.
If a common power supply is used, all the
inductive and capacitive loads (e.g. contac-
tors) connected to the power supply must
be connected to appropriate interference
suppression units.
closed
actuator
Safety
LA
LB
D1
D2
D3
D0
Safety guard
Read head
operating distance)
(actuator not in the
24 V
24 V
24 V
24 V
+LA
+LB
B
is reverse polarity
open
LA
LB
D0
D1
D2
D3