G6B-1174P-1-US DC5 Omron, G6B-1174P-1-US DC5 Datasheet - Page 4

no-image

G6B-1174P-1-US DC5

Manufacturer Part Number
G6B-1174P-1-US DC5
Description
RELAYS
Manufacturer
Omron
Series
G6Br
Datasheet

Specifications of G6B-1174P-1-US DC5

Rohs Compliant
YES
Relay Type
General Purpose
Contact Form
SPST-NO (1 Form A)
Contact Rating (current)
8A
Switching Voltage
380VAC, 125VDC - Max
Coil Type
Standard
Coil Current
40mA
Coil Voltage
5VDC
Turn On Voltage (max)
3.5 VDC
Turn Off Voltage (min)
0.5 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPST-NO (1 Form A)
Contact Rating @ Voltage
8A @ 250VAC
Control On Voltage (max)
3.5 VDC
Control Off Voltage (min)
0.5 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G6B-1174P-1-USDC5
G6B1174P1USDC5
■ Approved Standards
UL Recognized (File No. E41643) / CSA Certified (File No. LR31928)
Engineering Data
152
G6B-1114P-US
G6B-1114C-US
G6BU-1114P-US
G6BU-1114C-US
G6BK-1114C-US
G6BK-1114C-US
G6B-1174P-US
G6B-1174C-US
G6B-2114P-US
G6B-2114C-US
G6B-2214P-US
G6B-2214C-US
G6B-2014P-US
G6B-2014C-US
G6B-1114P-US
Maximum Switching Capacity
G6B-2114P-US, G6B-2214P-US, G6B-2014P-US
Maximum Switching Capacity
DC inductive load
(L/R = 7 ms)
DC inductive load
(L/R = 7 ms)
DC resistive load
AC inductive load
(cosφ = 0.4)
DC resistive load
Switching voltage (V)
AC inductive load
(cosφ = 0.4)
Switching voltage (V)
Power PCB Relay
Model
AC resistive load
AC resistive
load
G6B
SPST-NO
SPST-NO + SPST-NC
DPST-NO
DPST-NC
Electrical Service Life
Electrical Service Life
Contact form
250 VAC inductive load (cosφ = 0.4)
30 VDC inductive load (L/R = 7 ms)
G6B-1114P(C)-US
250 VAC/30 VDC
inductive load
(cosφ = 0.4, L/R = 7 ms)
Switching current (A)
G6B-1114P(C)-US
250 VAC/30 VDC resistive load
250 VAC resistive load
30 VDC resistive load
Switching current (A)
G6B-1174P(C)-US
250 VAC/30 VDC
resistive load
3 to 24 VDC
Coil rating
Note: The maximum coil voltage refers
Ambient Temperature vs.
Maximum Coil Voltage
to the maxi-mum value in a
varying range of operating power
voltage, not a continuous voltage.
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
5 A at 250 VAC (General Use) 80°C
5 A at 30 VDC (Resistive) 80°C
8 A at 250 VAC (General Use) 80°C
8 A at 30 VDC (Resistive) 80°C
5 A at 250 VAC (general use) 40°C
5 A at 30 VDC (resistive load) 40°C
Ambient temperature (°C)
G6B-1174P-US
G6B-1114P-US
Contact rating