G6DS-1AH 12DC Omron, G6DS-1AH 12DC Datasheet - Page 2

RELAY, PCB, SPNO, 12VDC

G6DS-1AH 12DC

Manufacturer Part Number
G6DS-1AH 12DC
Description
RELAY, PCB, SPNO, 12VDC
Manufacturer
Omron
Datasheet

Specifications of G6DS-1AH 12DC

Relay Type
Power
Coil Voltage Vdc Nom
12V
Contact Current Max
5A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Coil Resistance
1.2kohm
Coil Type
DC Coil, Sensitive
Coil Current
10mA
Nom
RoHS Compliant
Contact Configuration
SPST
Rohs Compliant
Yes
Specifications
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note: P level: λ 60 = 0.1 x 10
Note: The data shown above are initial values.
Rated voltage
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
Power consumption
Rated load
Contact material
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Failure rate (ref. value)
Contact resistance
Operate time
Release time
Insulation resistance
Dielectric strength
Impulse withstand voltage
Insulation
Distance
Tracking Resistance CTI)
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
PCB Power Relay – G6DS
64
Coil Ratings
Contact Ratings
Characteristics
2. Operating characteristics are measured at a coil temperature of 23°C.
3. “Max. voltage” refers to the maximum voltage that can be applied to the relay coil. It is not the maximum voltage that can be
1. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method.
2. The insulation resistance is possible between coil and contacts and between contacts of the same polarity at 500 VDC.
applied continuously.
Item
Item
Creepage (Typ) 6.4 mm
Clearance (Typ) 5.2 mm
-6
/operation.
5 VDC
36 mA
139 Ω
70% max. of rated voltage
5% min. of rated voltage
160% of rated voltage (at 23°C)
Approx. 180 mW
5 A at 250 VAC, 5 A at 30 VDC
AgNi
5 A
250 VAC, 30 VDC
5 A
1,250 VA, 150 W
5 mA at 24 VDC
100 mΩ max.
10 ms max.
5 ms max.
1,000 MΩ min. (at 500 VDC)
3,000 VAC, 50/60 Hz for 1 min between coil and contacts
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
6,000 V (1.2 x 50 µs) between coil and contacts
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s
Malfunction: 150 m/s
Mechanical: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical:
Operating: -40˚C to 85˚C (with no icing)
Operating: 5% to 85%
Approx. 2.3 g
175 V
Resistive load (cos φ = 1)
12 VDC
15 mA
800 Ω
Standard
100,000 operations min. (at 1,800 operations/hr) for standard type.
80,000 operations min. (at 1,800 operations/hr) for high-sensitivity type.
2
(standard type). 130 m/s
2
24 VDC
7.5 mA
3,200 Ω
5 VDC
24 mA
208 Ω
Approx. 120 mW
2 A at 250 VAC, 2 A at 30 VDC
2
Inductive load (cos φ = 0.4, L/R=7 ms)
(high-sensitivity type)
High-sensitivity
12 VDC
10 mA
1,200 Ω
24 VDC
5 mA
4,800 ΩΩ

Related parts for G6DS-1AH 12DC