RPBA BANNER ENGINEERING, RPBA Datasheet

no-image

RPBA

Manufacturer Part Number
RPBA
Description
POWER BLOCK MODULE SPST
Manufacturer
BANNER ENGINEERING
Datasheets

Specifications of RPBA

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Function
Module, Power Block
Technology
Photoelectric
Lead Free Status / Rohs Status
RoHS Exempt Product

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RPBAG-R
Manufacturer:
STEC
Quantity:
101
Printed in USA
Highly versatile modularized photoelectric sensing controls
MAXI-BEAM
Highly versatile, self-contained, modularized photoelectric
sensors; especially suited to industrial environments
Wide selection of rotatable sensor heads, power blocks, and
logic timing modules to suit any application
Power blocks for AC or DC operation and for switching of
AC or DC loads
Sensor heads include patented AID™ indicator device,
which lights a top-mounted LED when the sensor "sees" its
own modulated light source and pulses the LED at a rate
proportional to the received light signal strength
Status indicator LEDs on power block continuously indicate
the state of the output circuit
Models are available in all sensing modes
®
Sensors
P/N 32883F4A

Related parts for RPBA

RPBA Summary of contents

Page 1

MAXI-BEAM Highly versatile modularized photoelectric sensing controls Printed in USA ® Sensors • Highly versatile, self-contained, modularized photoelectric sensors; especially suited to industrial environments • Wide selection of rotatable sensor heads, power blocks, and logic timing modules to suit any ...

Page 2

MAXI-BEAM Modular Sensors Banner MAXI-BEAM sensors are highly versatile, self-contained, modularized photoelectric sensing controls that are ideally suited to industrial environments. The basic MAXI-BEAM is an ON/OFF switch consisting of three modules: a sensor head, a power block, and a ...

Page 3

... The addition of a programmable logic module can add process timing control as part of the MAXI-BEAM sensor assembly. 5) SELECT ACCESSORIES, as needed (see pages 15-16). MAXI-BEAM Dimensions Functional Schematic, MAXI-BEAM Sensor Head Exploded view, MAXI-BEAM Sensor ...

Page 4

MAXI-BEAM Sensing Mode OPPOSED Mode OPPOSED FIBER OPTIC Mode (glass fibers) RETROREFLECTIVE Mode 4 Sensor Heads Models Excess Gain RSBE & RSBR 1000 Range: 300 feet ( "HP" (high power) and wire) modes X 100 ...

Page 5

MAXI-BEAM Sensing Mode DIFFUSE Mode CONVERGENT Mode Powerful visible red beam detects small objects only a fraction of an inch away from backgrounds. Useful in many high-contrast color registration applications. FIXED-FIELD Mode Sensor Heads Models Excess Gain RSBD 1000 Range: ...

Page 6

MAXI-BEAM Sensing Mode FIBER OPTIC Mode (glass fibers) OPPOSED MODE OBJECT RETROREFLECTOR RETRO MODE OBJECT DIFFUSE MODE OBJECT FIBER OPTIC Mode (plastic fibers) OPPOSED MODE OBJECT DIFFUSE MODE OBJECT 6 Sensor Heads Models Excess Gain RSBF 1000 Range: see excess ...

Page 7

MAXI-BEAM Sensing Mode FIBER OPTIC Mode (glass fibers) OPPOSED MODE OBJECT RETROREFLECTOR RETRO MODE OBJECT DIFFUSE MODE OBJECT Programming the MAXI-BEAM Sensor Head MAXI-BEAM sensor heads may be programmed for sensor response time (and range) and for LIGHT/DARK operate. Each ...

Page 8

MAXI-BEAM RWB4 Wiring Base Power Block (order separately) DC Models RPBT RPBT-1 (for emitters) INPUT 30V dc, 20mA, exclusive of load cur- rent; 10% maximum ripple. OUTPUT: one open-collector NPN (current sinking) and one open-collector PNP (current sourcing) ...

Page 9

... As a general rule, if more than three or four MAXI-BEAM sensors using RPBR or RPBR2 power blocks must be connected to the same transformer-isolated ac circuit, consider the substitution of power block model RPBAR2 (for 105-130V ac) or model RPBBR2 (for 210-250V ac), which use conventional ac-to-dc power conversion circuitry. These power blocks connect exactly like model RPBR2, but do not exhibit the peak power demand of a phase-fired design ...

Page 10

... These blocks are designed to handle the inrush current of ac inductive loads like motor starters and solenoids. There is no mimimum load requirement, and they will interface directly to inputs of all ac programmable logic controllers (PLCs). Special order models RPBAT (120V ac) and RPBBT (240V ac) are available for interfacing to dc loads 100 milliamps. ...

Page 11

... RPBB START Hookup in Series with other MAXI-BEAMs MAXI-BEAMs which use RPBA or RPBB power blocks may be wired in series for the "AND" logic function. The total voltage drop across the series will be the sum of the individual voltage drops across each power block (approximately 3 volts per block) ...

Page 12

... MAXI-BEAM sensors cannot wire in series with other 2-wire sensors. If series connection of 2-wire AC sensors is required, consider models within the VALU- BEAM or MINI-BEAM sensor families. 4-wire ac power blocks can wire in series (see RPBA, RPBB). 2-wire MAXI-BEAMs with Parallel Contacts 2-wire MAXI-BEAM sensors may be wired in parallel with mechanical switch or relay con- tacts ...

Page 13

MAXI-BEAM Model RPBTLM Model RPBTLM is a miniature dc power block for MAXI-BEAM sensors. It may be used with any of the MAXI-BEAM sensor head models. The RPBTLM is supplied with stainless steel hardware used for assembly of the MAXI-BEAM ...

Page 14

MAXI-BEAM MAXI-BEAM Logic Module Specifications SUPPLY VOLTAGE: input power is supplied by the power block (see pages 8-13). RESPONSE TIME: RLM5: add sensor response delay of approximately 2% of maximum OFF-DELAY time. RLM8: no added response time for ONE-SHOT mode. ...

Page 15

... Model and Logic Functions RLM8 Program Definition MAXI-BEAM Accessories Replacement Upper Covers (Lens Assemblies) An upper cover consists of the optical element for the MAXI-BEAM sensor head. An upper cover may be used as a replacement part or for modifying the optical response of a sensor. Upper cover assemblies include lens, replacement bezel, o-ring, and stainless steel screws. ...

Page 16

... MAXI-BEAM to retrofit to installa- tions of MICRO-SWITCH models MLS8 or MLS9 sensors. Includes cable gland and lockwasher. Banner Engineering Corp. 9714 Tenth Ave. No. Minneapolis, MN 55441 HF1-2NPS This is a black nylon cable gland assembly for use with the MAXI-BEAM and other sensors having a 1/2- NPS conduit entrance. The flexible extension keeps the sensor cable from bending too sharply, and mimimizes cable fatigue due to repeated flexing ...