WLESS/CNFG/KIT STATUS, WLESS/CNFG/KIT Datasheet - Page 2

no-image

WLESS/CNFG/KIT

Manufacturer Part Number
WLESS/CNFG/KIT
Description
CONFIG TOOL, FOR WX WIRELESS SYSTEM
Manufacturer
STATUS
Datasheet

Specifications of WLESS/CNFG/KIT

Svhc
No SVHC (15-Dec-2010)
Accessory Type
Wireless Configuration Kit
Rohs Compliant
Yes
For Use With
Status Instruments Wireless Temperature Sensing Equipment
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Input
Analogue Outputs
1
Relay outputs
General
Environmental influences
1
Number of transmitters
Receiving frequency
Open air range
Measuring range limits
Configuration
Engineering Units
Number
Output signal:
- Current
- Voltage
Transmission behaviour
Load (at current output)
Load (at voltage output)
Setting time for temperature changes
Setting time after switching on or reset
Accuracy
Residual ripple
electrical isolation
Isolation voltage
Number
Relay
Contact rating
Contact life
Electrical isolation
Voltage supply
Amperage
Electrical connection
Electrical safety
Electrical isolation
Ambient temperature range
Storage temperature range
Temperature coefficient
Ambient conditions
Vibration resistant
EMC
- emitted interference
- interference resistance
- radio frequency spectrum
All accuracy specifications in % from the measuring range end value of 20 mA or 10 V
All accuracy specifications in % from the measuring range end value of 20 mA or 10 V
Max. 16 probes can be received per receiver.
868.4 MHz (Europe)
Max. 300 m when using the antenna wall holder and 10 m long antenna extension cable.
When installing the antenna directly onto the receiver, a reduced range of approx. 40 % must
be taken into account.
Depending on the sensor set
Using the front panel push buttons or using PC with our free software
° C, ° F, various units for potentiometer and voltage, can be set on the device or using the
setup program
4 analogue outputs for WRX900/04, 2 analogue outputs for WRX900/22
Adjustable using the front panel push buttons or using our free software and PC
(0 to 20) mA or (4 to 20) mA
(0 to 10) V
Linear, freely scalable. User linearization available when transmitter WTX700 is configured
with potentiometer or mV (current) sensors.
500 Ohm
10 k Ohm
The setting time depends on the transmission interval set in the probe.
5 s
±0.1%
(accuracy includes adjustment, linearisation, load influence and voltage supply influence)
±0.2%
The analogue outputs are electrically isolated from each other and the interfaces.
50 V DC
2 relay outputs for WRX900/22
N/O, configurable as an N/C
max. 3 A at AC 230 V resistive load
150 000 operations at 3 A / AC 230 V resistive load
350 000 operations at 1 A / AC 230 V resistive load
310 000 operations at 1 A / AC 230 V and cos phi > 0.7
Relay to analogue outputs and interface; test voltage AC 3700 V (reinforced insulation)
Relay to relay; test voltage AC 2300 V (basic insulation)
Combined operation of mains voltage AC 230 V and SELV or PELV voltage is not admissible
due to the basic insulation between the relays.
AC (110 to 240) V (+10 / -15) %, (48 to 63) Hz or AC / DC (20 to 30) V, (48 to 63) Hz
12 VA
Screw-type terminals up to 2.5 mm
as per DIN EN 61010, Part 1 Overvoltage category III, pollution degree 2, for installation into a
switch cabinet as per DIN EN 50178
The voltage supply and the analogue outputs, relays and interfaces are electrically isolated.
To 3.7 kV
±0.005%
Rel. humidity 85% without condensation as per DIN EN 60721-3-3 3K3
Max. 1 g at (10 to 55) Hz as per DIN IEC 60068-2-6
DIN EN 61326-1
Class A - Only for industrial use -
Industrial requirements
ETSI EN 300220-1, V 1.3.1
(-20 to +50) ° C without condensation (even with close mounting)
(-30 to +70) ° C
1
1
1
/° C; per ° C deviation from the reference temperature 22 ° C (±3 ° C)
2