Datasheet

Specifications of E3XCN21

Accessory Type
Amplifier Cable
For Use With
Digital Fiber Amplifier
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Rating/Performance
Amplifier units
Prewired
E3X-DA-N
Light source
(wave length)
Power supply voltage
Power consumption
Con-
trol
output
Protective circuits
Re-
spons
e time
Sensitivity setting
Func-
tions
Indicator lamp
Display timing
Display direction
Optical axis adjustment
function
Ambient lighting
Ambient temperature
Ambient humidity
Item
ON/OFF output
Monitor output
Super-high-
speed mode:
Standard mode: Operation/reset: 1 ms each
Super-long-dis-
tance mode:
Timer functions
Automatic pow-
er control (APC)
Zero reset
Initial reset
Monitor focus
Model
output
output
NPN
PNP
Type
Red LED (660 nm)
12 to 24 VDC ±10%, ripple (p-p) : 10% max.
Normal: Power consumption 960 mW max. (power consumption 40 mA max. at supply voltage 24 V) Eco
mode: Power consumption 720 mW max. (power consumption 30 mA max. at supply voltage 24 V) Digital
display OFF: Power consumption 600 mW max. (power consumption 25 mA max. at supply voltage 24 V)
Load current 50 mA (residual voltage NPN/PNP: 1 V max. each) Open collector output type (depends on the
NPN/PNP output format) Light-ON/Dark-ON, switch selectable
Reverse polarity protection, output short-circuit protection, mutual interference prevention (possible for up to
10 amplifiers)
0.25 ms for operation and reset respectively
4 ms for operation and reset respectively
Teaching or manual method
OFF delay 0 to 200 ms (1 to 20: 1 ms increments, 20 to 200 ms: 5 ms increments), when the Mobile Control
is used, select either OFF delay, ON delay or one shot.
Fiber-optic current digital con-
trol
Yes (negative indication possible)
Yes (setting conditions initialized)
Operation indicator (orange), 7-segment digital incident level display (red), 7-segment digital incident level
percent display (red), incident level & threshold value double-bar display (green, red), 7-segment digital
threshold value display (red)
Normal/peak hold/bottom hold selectable
Normal/reverse selectable
Yes (hyper flashing emission function)
Incandescent lamp: 10,000 lux max. Sunlight 20,000 lux max.
Operating: Groups of 1 to 3 amplifiers: -25 to +55°C, Groups of 4 to 11 amplifiers: -25 to +50°C, Groups of
12 to 16 amplifiers: -25 to +45°C Storage: -30 to +70°C (with no icing and condensation)
Operating/Storage: 35% to 85% RH (with no condensation)
E3X-DA11-N
E3X-DA41-N
Standard
models
---
---
1 to 5 VDC,
load 10 k
min.
Upper and
lower limit val-
ues of output
range can be
set per digital
value of 100
E3X-DA21-N E3X-DAB11-N E3X-DAG11-N E3X-DAH11-N
E3X-DA51-N E3X-DAB41-N E3X-DAG41-N E3X-DAH41-N
Monitor-out-
put models
Blue LED
(470 nm)
Mark-detecting models
Green LED
(525 nm)
---
Infrared LED
(870 nm)
Infrared
models
---
---
Red LED (660 nm)
Fiber-optic current digital
control
Water-resis-
E3X-DA11V
E3X-DA41V
tant models
0.5 ms for
operation
and reset
respectively
2 ms for
operation
and reset
respectively
7 ms for
operation
and reset
respectively
E3X-DA11TW
E3X-DA41TW
Twin-output
models
A-423