HXS 10-NP/SP3 LEM, HXS 10-NP/SP3 Datasheet

CURRENT TRANSDUCER

HXS 10-NP/SP3

Manufacturer Part Number
HXS 10-NP/SP3
Description
CURRENT TRANSDUCER
Manufacturer
LEM
Datasheet

Specifications of HXS 10-NP/SP3

Current Measuring Range Ac
DC, AC, Pulsed, Mixed
Current Measuring Range Dc
DC, AC, Pulsed, Mixed
Operating Frequency Range
DC To 50kHz
Sensor Output
Voltage
Svhc
No SVHC
Accuracy
1%
Response Time
5µs
Current Consumption
22mA
Current Range Ac
DC, AC, Pulsed, Mixed
Current Range Dc
DC, AC,
Rohs Compliant
Yes
Accuracy %
1%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current Transducer HXS 10-NP/SP3
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
Primary nominal
r.m.s. current
Serial
±10
V
V
R
R
C
V
I
X
TCV
TCV
TCV
TC
V
t
t
di/dt
f
T
T
dCp
dCl
CTI
m
LEM Components
C
ra
r
A
S
OUT
REF
C
OM
OUT
L
L
L
Electrical data
Accuracy - Dynamic performance data
General data
I
OUT
REF
OUT
G
PN
/ V
(A)
Analog output voltage @ I
Internal Reference
Output load resistance
Output impedance
Max. output capacitive load
Supply voltage (± 5 %)
Current consumption @ V
Accuracy
Linearity 0.. I
Thermal drift of V
Thermal drift of V
Thermal drift of the gain
Residual voltage @ I
Reaction time @ 10 % of I
Response time @ 90 % of I
di/dt accurately followed
Output noise (DC ..10 kHz)
Frequency bandwidth (-3 dB)
Ambient operating temperature
Ambient storage temperature
Creepage distance
Clearance distance
Comparative tracking index (Group I )
UL94 classification
Mass
Standards
REF
Parallel
±20
Thermal drift of V
2)
.. 3 x I
@ I
PN
(DC .. 1 MHz)
PN
PN
Primary current
measuring range
Serial
±30
, T
OUT
REF
OUT
1)
A
@ I
P
- Output voltage
= 25°C
I
/ V
= 0, after an overload of 3 x I
P
V
V
(A)
REF
REF
P
REF
I
= 0
P
P
C
PN
Output impedance
Load impedance
@ I
= 0
Parallel
= 5 V
PN
±60
3)
P
= 0
All Data are given with a R
PN DC
typ. 200
Type
HXS 10-NP/SP3
V
V
2.5 ± 0.025
5
22
<±0.7
< 3
< 5
> 50
< 15
< 40
DC .. 50
- 40 .. + 85
- 40 .. + 85
> 5.5
> 5.5
> 600
V0
10
EN 50178 (97-10-01)
±0.05
±0.5
±0.4
±0.01
±0.2
±1
±1
REF
REF
2
10
1
200
± (0.625·I
± 0.0125
% of reading/K
L
= 10 k
% of I
% of I
% of I
% of I
P
m V p p
m V p p
/I
mV/K
mV/K
PN
A/µs
%/K
m m
m m
kHz
mA
) V
k
k
µF
µs
µs
°C
°C
PN
PN
PN
PN
V
V
V
V
g
I
Features
Special Feature
Advantages
Applications
PN
Hall effect measuring principle
Multirange current transducer
through PCB pattern lay-out
Galvanic isolation between primary
and secondary circuit
Isolation test voltage 2500V
Low power consumption
Extremely low profile, 10mm
Single power supply +5V
Fixed offset & gain
Two separate primary windings for
dual phase measurement
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference.
Internal & external reference
AC variable speed drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
= 10 A
DUAL PHASE
w w w .lem.com
041222/2

Related parts for HXS 10-NP/SP3

HXS 10-NP/SP3 Summary of contents

Page 1

... Current Transducer HXS 10-NP/SP3 For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Electrical data Primary nominal Primary current r.m.s. current measuring range I ( Serial Parallel Serial Parallel ± ...

Page 2

... Current Transducer HXS 10-NP/SP3 Insulation category V Nominal Voltage b with IEC 61010-1 standards and following conditions - Single insulation - Over voltage category III - Pollution degree 2 - Heterogeneous field V Nominal Voltage b with EN 50178 standards and following conditions - Reinforced insulation - Over voltage category III - Pollution degree 2 ...

Page 3

... HXS 10-NP/SP3 Dimensions (in mm) 0.6 Ref Out GND Vc 4-0.5*0.25 7.7 Primary current Primary nominal maximum I [A] connections PN 10 Serial Parallel 20 Mechanical characteristics General tolerance Fastening & connection of primary jumper Recommended PCB hole Fastening & connection of secondary Recommended PCB hole LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. ...