LA 100-P/SP13 LEM, LA 100-P/SP13 Datasheet - Page 3

CURRENT TRANSDUCER

LA 100-P/SP13

Manufacturer Part Number
LA 100-P/SP13
Description
CURRENT TRANSDUCER
Manufacturer
LEM
Datasheet

Specifications of LA 100-P/SP13

Current Measuring Range Ac
± 160
Current Measuring Range Dc
± 160
Operating Frequency Range
DC To 200kHz
Supply Voltage Range Dc
12V To 15V
Sensor Output
Current
Svhc
No SVHC
Accuracy
0.7%
Response Time
1µs
Current Consumption
10mA
Current Range Ac
± 160
Rohs Compliant
Yes
Accuracy %
0.7%
Bandwidth
200kHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
070720/3
Dimensions LA 100-P/SP13
Mechanical characteristics
Bottom view
Front view
General tolerance
Primary through-hole
Fastening & connection of secondary
Recommended PCB hole
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
(in mm. 1 mm = 0.0394 inch)
± 0.2 mm
12.7 x 7 mm
3 pins
0.63 x 0.56 mm
0.9 mm
Remarks
I
Temperature of the primary conductor should not exceed
100°C.
Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
In order to achieve the best magnetic coupling, the primary
windings have to be wound over the top edge of the device.
S
is positive when I
Connection
P
flows in the direction of the arrow.
w w w .lem.com
Left view
Page 3/3

Related parts for LA 100-P/SP13