E3X-NA11F Omron, E3X-NA11F Datasheet - Page 18

Fiber Amplifier

E3X-NA11F

Manufacturer Part Number
E3X-NA11F
Description
Fiber Amplifier
Manufacturer
Omron
Type
High Speed Detectionr
Datasheet

Specifications of E3X-NA11F

Sensor Output
NPN
Length/height, External
31.5mm
Sensor Housing
Rectangular
Response Time
40ms
Sensing Range Min
0.3mm
Output Type
NPN
Sensor Input
Fiber Optic
External Width
10mm
External Depth
64.3mm
Operating Temperature Max
55°C
Operating Temperature Min
-25°C
Rohs Compliant
Yes
Fiber Optic Sensor Type
High Speed Detection
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
18
E3X-SD/-NA
Operating Procedure
E3X-SD@
A 7-segment display showing excess gain is provided in
addition to the orange operation indicator.
Use these when adjusting the light axis and setting the
sensitivity at setup.
The sensitivity can be set with the UP and DOWN Keys similar
to using an adjuster knob. The sensitivity can also be easily
set by using the following three teaching functions.
The sensitivity can be set to the maximum. This is the optimal
setting for resistance against the effects of dust.
Two points (one with the workpiece and the other without) are
detected, and the operating level is set to the midpoint.
Changes within a time are detected, and the operating level is
set to the midpoint between the maximum and the minimum
values of the changes. This setting is optimal for when the
workpieces cannot be stopped.
Set the TEACH/RUN selector
switch to TEACH.
Press the UP Key for 3 s min.
Set the TEACH/RUN selector
switch to RUN (start of mea-
surement).
Set the TEACH/RUN selector
switch to TEACH.
Press the UP Key with the
workpiece present.
Press the UP Key with the
workpiece not present.
Set the TEACH/RUN selector
switch to RUN (start of mea-
surement).
Set the TEACH/RUN selector
switch to TEACH.
Press the UP Key.
1
Display/indicator status (for L/ON)
2
2-1. Maximum Sensitivity Setting
2-2. Teaching with/without a Workpiece
Operation description
2-3. Automatic Teaching
Operation description
Operation description
Displays
Sensitivity Setting
Operation indicator
Excess gain display
Switch/Key
TEACH
TEACH
Switch/Key
TEACH
TEACH
Switch/Key
TEACH
UP
UP
UP
UP
RUN
RUN
RUN
RUN
RUN
Excess gain
(10 times)
999%
100%
0%
Display
Display
Display
incident light or
interrupted light
interrupted light
Stable incident
90% to 110%
Description
110% min.
90% max.
Unstable
Unstable
Stable
light
E3X-NA@
A bar display (with four green and one red) showing excess
gain is provided in addition to the orange operation indicator.
Use these when adjusting the light axis and setting the
sensitivity at setup.
Hold down the UP Key during
detection. Let the workpiece
pass while the key is held down.
Set the TEACH/RUN selector
switch to RUN (start of mea-
surement).
1
Display/indicator status (for L/ON)
Operation description
Displays
Operation indicator
Excess gain level display
Switch/Key
TEACH
UP
RUN
110% to 120%
90% to 110%
Excess gain
80% to 90%
120% min.
80% max.
Approx.
Approx.
Approx.
Approx.
Approx.
level
Display
interrupted light
interrupted light
incident light or
Stable incident
Description
Unstable
Unstable
Stable
light