FE-MLS8C PEPPERL & FUCHS, FE-MLS8C Datasheet - Page 3

Photoelectric Sensor

FE-MLS8C

Manufacturer Part Number
FE-MLS8C
Description
Photoelectric Sensor
Manufacturer
PEPPERL & FUCHS
Type
Fiber Opticr
Datasheets

Specifications of FE-MLS8C

Output Current
10A
Sensor Output
Relay
Sensor Housing
Rectangular
Peak Reflow Compatible (260 C)
No
Output Type
Relay
Sensor Input
Optical
Supply Voltage Max
132VAC
Sensing Range Max
12m
Body Style
Rectangular
Brand/series
FE-MLS8C
Function
Proximity
Ip Rating
IP67
Output
Relay
Primary Type
Photoelectric
Range, Measurement
12 m
Sensing Mode
Retro-Reflective
Technology
Photoelectric
Termination
Screw
Voltage, Supply
132 VAC
Leaded Process Compatible
No
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
FE-MLS8C Wiring and Alignment
1.
2a. Connect the load and load supply (common) to
2b. Solid state relay connections shown below.
3.
4.
FE-MLS8C/9C Series Specifi cations
ELECTRICAL CONTACT RATING
LED(s)
POWER CONSUMPTION
MECHANICAL LIFE OF RELAY
OPERATING MODE
PROTECTION (IEC)
LIGHT SOURCE
TEMPERATURE RANGE
HOUSING MATERIAL
ELECTRICAL CONNECTION
Remove the rear housing cover.
selected terminals. Standard relay connections
shown below.
Connect AC power (through the conduit opening) to
the “LINE” terminals. The white and black input wires
must be connected to the proper terminals. See the
control nameplate for correct line volage.
Set the mode selector switch to the light operate (L.O.)
position.
LENS
C 1
C 1
NO 1
NO 1
NC 1
Terminations
Series Specifi cations
NC 2
NO 2
C 2
Glass reinforced polycarbonate
Line
Line
500,000 operations
Light on/dark on
-40ºF to +158ºF
Infrared LED
115V/10A
Yes (1)
Plastic
connection
≤5VA
IP67
Terminal
5.
6.
7.
8.
9.
10. If direct On-Off dark operation is desired (relay
11. Insert optional function card fi rmly (if used) and adjust
12. Replace cover and tighten both screws.
Apply power. The alignment indicator light visible at
the top of the control will remain OFF with no refl ector
present.
Position the refl ector opposite the lens. The indicator
will turn On when control and refl ector are in
alignment.
Center the refl ector in the beam (by watching the
indicator as the refl ector is moved up, down, left and
right). Use adhesive or a #8 screw (for the 3-inch disc)
to mount the refl ector.
Block the invisible beam with the object to be
detected. When the beam is blocked, the indicator will
be Off.
Fully tighten the mounting bolts, and again block the
beam to recheck alignment.
energized when the beam is blocked), move the mode
selector switch to the dark operate (D.O.) position.
pots as required.
FE-MLS8C and FE-MLS9C
Functional Block Diagram
Photoelectric Sensors
D.O.
C 1 NO 1 NC 1 NC 2 NO 2 C 2
Relay
For Optional Card
Lens
L.O.
Pin Connect
Receiver
Photo
Terminations
Amplifier
Supply
Power
OSC
Pulsing
L.E.D.
Line
Indicator
L.E.D.
Red
567

Related parts for FE-MLS8C