Specifications of S18SN6LQ

Output Current
150mA
Sensor Output
NPN
Supply Voltage Range Dc
10V To 30V
4
Supply Voltage and
Current
Supply Protection
Circuitry
Output Configuration
Output Rating
Output Protection
Circuitry
Output Response Time
Repeatability
Indicators
Construction
Environmental Rating
Connections
Operating Conditions
Vibration and Mechanical
Shock
Certifications
P/N 121522
S18 Sensors – dc-Voltage Series
10 to 30V dc (10% max. ripple); supply current (exclusive of load current):
Protected against reverse polarity and transient voltages
SPDT solid-state dc switch; NPN (current sinking) or PNP (current sourcing), depending on model
Light Operate: N.O. output conducts when sensor sees its own (or the emitter’s) modulated light
Dark Operate: N.C. output conducts when the sensor sees dark; the N.C. (normally closed) output may be
150 mA maximum (each) in standard hookup. When wired for alarm output, the total load may not exceed 150 mA.
OFF-state leakage current: < 1 microamp @ 30V dc
ON-state saturation voltage: < 1V @ 10 mA dc; < 1.5V @ 150 mA dc
Protected against false pulse on power-up and continuous overload or short circuit of outputs
Opposed mode: 3 ms ON, 1.5 ms OFF
Retro, Fixed-Field and Diffuse: 3 ms ON and OFF
NOTE: 100 ms delay on power-up; outputs do not conduct during this time.
Opposed mode: 375 µs
Retro, Fixed-Field and Diffuse: 750 µs
Repeatability and response are independent of signal strength.
Two LEDs (Green and Yellow)
Green ON steady: power to sensor is ON
Green flashing: output is overloaded
Yellow ON steady: N.O. output is conducting
Yellow flashing: excess gain marginal (1 to 1.5x) in light condition
PBT polyester housing; polycarbonate (opposed-mode) or acrylic lens
Leakproof design rated NEMA 6P, DIN 40050 (IP69K)
Temperature: -40° to +70° C (-40° to +158° F)
Maximum relative humidity: 90% at 50° C (non-condensing)
All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max., double
amplitude 0.06" acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for
non-operation)
2 m (6.5') or 9 m (30') attached cable or 4-pin Euro-style quick-disconnect fitting
Emitters, Non-Polarized, Retro, Diffuse: 25 mA
Receivers: 20 mA
Polarized Retroreflective: 30 mA
Fixed-Field: 35 mA
wired as a normally open marginal signal alarm output, depending upon hookup to power supply