SDX005IND4 SENSYM, SDX005IND4 Datasheet
SDX005IND4
Specifications of SDX005IND4
Related parts for SDX005IND4
SDX005IND4 Summary of contents
Page 1
... ELECTRICAL CONNECTION 1 out + GND out - Note: The polarity identicated is for pressure applied to P2 (backward gage). SDX...IND4 Series Scale ½ inch The PC board area used by each DIP is approximately 0.26 square inches. This extremely small size enables the use of multiple sensors in limited available space ...
Page 2
... PRESSURE SENSOR CHARACTERISTICS (all devices) Maximum ratings Supply voltage V S Lead temperature (soldering 4 sec.) STANDARD PRESSURE RANGES Part number Operating pressure SDX005IND4 0...5 "H 0...10 "H SDX010IND4 PERFORMANCE CHARACTERISTICS ° ° Specification notes: 1. Reference conditions (unless otherwise noted): supply voltage, V pressure applied to port 2. ...
Page 3
... The SDX...IND4 series devices give a voltage output which is directly proportional to applied pressure. The gage devices will give an increasing positive going output when increasing pressure is applied to the pressure port. The devices are ratiometric to the supply voltage and changes in the supply voltage will cause proportional changes in the offset voltage and full scale span ...
Page 4
... H 2 Sensortechnics and Sensym reserve the right to make changes to any products herein. Sensortechnics and Sensym do not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. ...