MVS060802 COMUS, MVS060802 Datasheet - Page 4

Vibration Sensor

MVS060802

Manufacturer Part Number
MVS060802
Description
Vibration Sensor
Manufacturer
COMUS
Datasheets

Specifications of MVS060802

Beam Angle
60°
Switching Voltage
15V
Body Material
Metal
Sensor Body Material
Metal
Datasheet
1. Operating Conditions
* Current consumption is determined by the resistance of the application circuit and the supply voltage. The sensor is
2. Soldering Process
Reflow Soldering Process 260° C, 10 sec
3. Functionality
A mobile, gilded micro sphere is located inside the hollow space of the sensor. When moving,
the micro sphere bridges two gilded contacts by switching over from a high resistive to a low
resistive state. When the Sensor is at rest, it is not necessarily closed. Only in 70% - 99% of
time the sensor will be closed when at rest.
The figure shows the typical characteristics of the sensor in excitation and rest.
Supply voltage
Current
R Open
R Closed
Operating ambient temperature
fully passive, requires no signal conditioning, and operates with currents a low as 0.2 µA.
(e.g. max. Icc 0.2µA at Vcc 2V and R 10Meg)
(e.g. max. Icc 2.0µA at Vcc 2V and R 1Meg)
Sensor usually closed
PARAMETER
at rest
180°
Figure 1: Characteristic of the sensor MVS0608.02
V
I
R
R
T
CC
amb
CC
O
C
 Sensolute GmbH, 2011
SYMBOL
270°
90°
+1.80
-
< 100
-20
MIN
+15
2
> 30
-
+70
MAX
Sensor usually closed
at rest
Sensitivity
high
low
Vdc
mA
MOhm
Ohm
° C
MVS0608.02
UNIT
4 / 9

Related parts for MVS060802