E32-R16 Omron, E32-R16 Datasheet - Page 79

RETRO REFLECTIVE,1-1.2CM

E32-R16

Manufacturer Part Number
E32-R16
Description
RETRO REFLECTIVE,1-1.2CM
Manufacturer
Omron
Datasheets

Specifications of E32-R16

Rohs Compliant
YES
Sensing Method
Retroflective
Sensing Distance
150 mm to 1500 mm
Light Source
LED
Amplifier Type
Separate Digital Amplifier
Connection
Prewired Cable
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
78
Fiber Optic and Laser Optic Amplifiers
■ Specifications
Note: *1. When differential output is selected for the output setting, the second channel output is 200 µs for the operation and reset respectively.
Item
Light source (wavelength)
Supply voltage
Power comsumption
Control output
Circuit protection
Response
time
Functions
Weight (packed state)
*2. Communications are disabled if the detection mode is selected during high-speed mode; the communications functions for mutual
*3. Mutual interference prevention can be used for up to 5 Units (10 channels) if power tuning is enabled.
interference prevention and the Mobile Console will not function.
High-
speed
mode
Standard mode
High-resolution mode 4 ms for operation and reset respectively
Power tuning
Timer function
Automatic power
control (APC)
Zero-reset
Initial reset
Mutual interference
prevention
I/O settings
Model NPN output
NPN
PNP
PNP output
Type
Red LED (650 nm)
12 to 24 DVC ±10%, ripple (p-p) 10% max.
1,080 mW max. (current consumption: 45 mA max. at power supply voltage of 24 VDC)
Load power supply voltage: 26.4 VDC; NPN/PNP open collector;
load current: 50 mA max.: residual voltage: 1 V max.
Reverse polarity for power supply connection, output short-circuit
130 µs (*1) for operation and reset respectively
1 ms for operation and reset respectively
Light emmission power and reception gain, digital control method
Select from OFF-delay, or ON-delay, one-shot timer.
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments,
200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments)
High-speed control method for emission current
Display can be reset to zero when required (negative values can be displayed).
Settings can be returned to defaults as required.
Possible for up to 9 Units (18 channels) (*2, *3)
Output setting (Select from channel 2 output, AND, OR, leading edge sync, falling edge sync,
or differential output)
Approx. 100 g
E3X-MDA11
E3X-MDA41
2-channel models
Approx. 55 g
E3X-MDA6
E3X-MDA8

Related parts for E32-R16