06259 GREENLEE TEXTRON, 06259 Datasheet - Page 42

Tools

06259

Manufacturer Part Number
06259
Description
Tools
Manufacturer
GREENLEE TEXTRON
Datasheet

Specifications of 06259

For Use With
Cable Caster
Lead Free Status / RoHS Status
na
274
= ReplacemenT paRT
T-Bug
TelScout
sPeCIFICatIoNs
environmental
Power
®
Digital Signal Identifier
®
= accessoRy
TS100
Temperature –
Operating: 17° F to 92°F (-15° C to +60° C).
Non-operating: 12° F to 97° F (-20° C to +65° C).
Humidity – 95% RH, non-condensing.
Shock (test specification) – Survives drop of 2 m to
concrete in standard soft case.
Safety – EN 61010-1 and EN61010-031.
EMC – EN61326.
Mains Operation –
Voltage Ranges: 110 V, 220 V, 240 V with appropriate AC
to DC adapter.
Battery Operation –
Operating Time: 6 hrs. continuous.
Battery Saver: Selectable for 5 to 30 minutes or disabled.
• Used to detect digital signals on twisted pair cables, identify and isolate digital
• Operation is non-invasive and does not involve metallic contact so there’s
• Simple to use – just place the probe between the pairs in question.
• Differential amplifier saves time by allowing the technician to determine
• False readings due to noise are virtually eliminated.
• Continuous self test ensures that the unit is functioning properly.
• Emits both visible and audible indication when digital signals are present.
• Patented.
• Twisted Pair and Coax Testing in a Single Unit (optional).
• One-Step Setup.
• Automatic and Manual Instrument Control Mode.
• 45 kilofeet Fault Location Capability.
• Rugged – Survives 6 foot (2m) Drop.
• Powered from AC Mains or Rechargeable Internal Battery.
• Single-Button Zoom Function.
• Short Pulse Width Option (Includes Coax Testing Capability).
• Pair Comparison Mode.
• Splits/Crosstalk Mode.
• Intermittent Fault Location.
• Measures Distance to Fault in Feet, Meters, or Time.
• Configurable for Any Cable Type and Vp (0.300 to 1.000).
• Internal Memory Waveform Storage and Trace Upload to PC Software
• Serial Printer Output for Stored or Displayed Waveforms.
• Accurate (±3 ft. at 10,000 ft.)
• On-line Tutorials.
• Large Backlit Display.
Cat. No.
0134-0500
Cat. No.
TS100-01
650391700
pairs for special handling and help technicians avoid accidentally putting pairs
out of service.
no risk of service interruption.
whether the signal is truly present or is an induced signal from adjacent pairs.
(MCTAP-Option).
Physical
UPC No.
60764
UPC No. DesCrIPtIoN
60520
60754
TelScout TS100-01 Metallic TDR
Leads
DesCrIPtIoN
T-Bug Digital Signal Identifier
Dimensions
Height
Width
Depth
Weight
Net
3.5
6.4
12
10
in.
lb.
www.greenlee.com
mm
30
25
kg
3
9