Specifications of RNF-150-1-0-SP

Body Material
Polyolefin
Shrink Ratio
2
I.d. Supplied
25.4mm
I.d. Max Recovered
0.5"
Wall Thickness Recovered
0.019"
Accessory Type
Heat-Shrink Tubing
Color
Black
Diameter
25.4 mm (1 in)
Chemical Resistant
Yes
Minimum Shrink Temperature
+ 110 C
Maximum Temperature
+ 150 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Specification values
Physical
Electrical
Chemical
Note: Consult RT-370 for specific details about test procedures.
Raychem is a trademark of Tyco Electronics Corporation.
Users should independently evaluate the suitability of the product for their application.
Tyco Electronics Corporation
300 Constitution Drive
Menlo Park, CA 94025-1164
USA
Tel: (800) 926-2425 (US & Canada)
Tel: +1 (650) 361-3860 (All other countries)
All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their application. Tyco Electronics Corporation makes
no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Tyco Electronics Corporation’s only obligations are those in the Standard Terms and
Conditions of Sale for these products and in no case will Tyco Electronics Corporation be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of the
product. Tyco Electronics Corporation’s Specifications are subject to change without notice. In addition, Tyco Electronics Corporation reserves the right to make changes in materials or processing
without notification to the Buyer which do not affect compliance with any applicable specification.
For more information about this product visit www.tycoelectronics.com
Property
Dimensions
Longitudinal change
Concentricity as supplied
Weight per length as supplied
Recovery angle
Tensile strength
Ultimate elongation
Secant modulus (as supplied)
Low-temperature flexibility
(4 hours at -55°C/-67°F)
Heat shock
(4 hours at 250°C/482°F)
Dynamic cut-through
(135°C/275°F)
Heat resistance
(336 hours at 225°C/437°F)
Followed by test for:
Ultimate Elongation
Color
Dielectric strength
Volume resistivity
Corrosive effect
Copper mirror corrosion
(16 hours at 160°C/320°F)
Copper contact corrosion
(16 hours at 175°C/347°F)
Copper stability
(168 hours at 180°C/356°F)
Followed by test for:
Ultimate elongation
Flammability
Fungus resistance
Followed by tests for:
Tensile strength
Ultimate elongation
Dielectric strength
Water absorption
(24 hours at 23°C/73°F)
Fluid resistance
(24 hours at 50°C/122°F) in:
JP-8 fuel (MIL-T-5624)
Hydraulic fluid (MIL-H-5606)
Aviation gasoline100/300
(MIL-G-5572)
Water
Lubricating oil (MIL-L-23699)
Followed by tests for:
Dielectric strength
Tensile strength
Faraday Road
Dorcan, Swindon, SN3 5HH
United Kingdom
Tel: +44 1793 528171
Unit
mm (inches)
percent
percent
lb./100 ft. (kg./100 m) max.
degrees
psi (Mpa)
percent
psi (Mpa)
lb. (kg.)
percent
volts/mil (kV/mm)
ohm-cm
percent
psi (Mpa)
percent
volts/mil (kV/mm)
percent
volts/mil (kV/mm)
psi (Mpa)
3816 Noborito, Tama-ku
Kawasaki, Kanagawa 214-8533
Japan
Tel: +81 44 900 5102
Requirement
See reverse
+0, -10
70% minimum
See reverse
5 maximum
4000 (27.6) minimum
300 minimum
25,000 to 100,000 (172 to 690)
No cracking
No dripping, flowing,
or cracking
5 (2.3) minimum
250 minimum
MIL-STD-104, Class I
500 (19.7) minimum
10
Noncorrosive
Copper removal
5% maximum
No blackening or pitting
of copper
No brittleness, glazing, or severe
discoloration of tubing. No pitting
or blackening of copper.
250 minimum
25% maximum flag burn; no
burning of cotton; no flaming or
glowing longer than 60 seconds
4000 (27.6) minimum
300 minimum
500 (19.7) minimum
0.5 maximum
400 (15.8) minimum
2000 (13.8) minimum
11
minimum
Asia Pacific Headquarters
26 Ang Mo Kio, Industrial Park 2
Singapore 569507
Tel: +65 4866 151
Method of test
ASTM D 2671
ASTM D 2671
ASTM D 2671
See note below
See note below
ASTM D 2671
ASTM D 2671
ASTM D 2671
AMS-DTL-23053
ASTM D 2671
ASTM D 3032
See note below
ASTM D 2671
ASTM D 2671
MIL-STD-104
ASTM D 2671
ASTM D 2671
ASTM D 2671
ASTM D 2671
Procedure A
ASTM D 2671
Procedure B
ASTM D 2671
Procedure B
ASTM D 2671
UL 224, VW-1
ASTM D 2671
Procedure C
ISO 846
Method B
ASTM D 2671
ASTM D 2671
ASTM D 2671
ASTM D 2671
ASTM D 2671
ASTM D 2671
ASTM D 2671