175-300 Watts
HUL Series
Specification
Input
Output
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current • <1.5 mA at 230 VAC / 50 Hz
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Total Regulation
Over/Undershoot
Transient Response
Ripple & Noise
Overvoltage Protection • 130% on output 1 only, recycle input to
Overtemperature
Protection
Overload Protection
Short Circuit Protection • Trip and restart (Hiccup mode)
Temperature
Coefficient
Remote Sense
Remote On/Off
Fan Output
• 90-132 VAC, 180-264 VAC (auto-ranging)
• 47-63 Hz
• HUL175: 4.4 A max at 115 VAC,
• 35 A at 115 VAC, 70 A max at 264 VAC
• Passive PFC, meets EN6100-3-2, -3
• See tables
• ±5% on output 1
• ±1% max for single/main output
• See tables & note 1 for 175 W model
• 1 s max
• 20 ms max
• >15 ms at 115 VAC
• ±1% max for single output models,
• <5% max
• 5% max deviation, recovery to within
• 1% pk-pk (50 mV max for 3.3 V output)
• Shuts down when ambient temperature
• 110-135% of total power, auto recovery
• ±0.1%/°C
• HUL175 only. Compensates for 0.5 V drop
• On = Logic High or Open
• 12 V, 300 mA
2.2 A max at 230 VAC
HUL200: 5.0 A max at 115 VAC,
2.5 A max at 230 VAC
HUL300: 6.3 A max at 115 VAC,
3.15 A max at 230 VAC
+25 °C cold start
±5% for auxiliary outputs
±5% max for multiple output models
1% in 500 µs for a 50% load change
reset
exceeds +85 °C, auto recovery
on 3.3 V output
Off = Logic Low or Short
Not available on HUL175
•
•
•
•
•
•
•
General
Environmental
EMC & Safety
Efficiency
Isolation
Switching Frequency
Power Density
Power Fail Detect
MTBF
Operating Temperature • 0 °C to +60 °C, derate linearly from 100%
Cooling
Operating Humidity
Storage Temperature
Operating Altitude
Shock
Vibration
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
Compact Size, Low Profile
Up to 5.85 W/in
Single & Multiple Outputs
Convection-cooled Ratings
Remote On/Off
Power Fail Detect
12 V Fan Supply
• 80% typical
• 3000 VAC Input to Output,
• 42 kHz typical
• HUL175: 4.51 W/In
• On = Logic high 100-500 ms after outputs
• 100 kHrs per MIL-HDBK-217F
• See notes
• 5-90% RH, non-condensing
• -20 °C to +85 °C
• 3000 m
• 15 g (non-operation), 11 ms (half sine
• 10-55 Hz (non-operation) 2 g, sweep time
• EN55022 and FCC, level B
• EN61000-3-2
• EN61000-3-3
• EN61000-4-2, level 4 Perf Criteria A
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 10 V Perf Criteria A
• EN61000-4-11, 30% 10 ms,
• EN60950, UL60950, CSA22.2 No. 950
3
HUL300: 4.41 W/In
with regulation
Fail = Logic low at least 1 ms prior to loss
of output
at +40 °C to 50% at +60 °C
(level A - 300 W) conducted
70% 100 ms, 95% 5000 ms,
Perf Criteria A, B, B
per cUL, CE Mark
Power Density
1500 VAC Input to Ground,
500 VAC Output to Ground
wave), 3 times for each axis
3 mins, 60 mins/axis
xppower.com
3
3
, HUL200: 5.85 W/In
3
,