6900 3M, 6900 Datasheet
![CONN F/OPTIC CRIMPLOK SC MM](/photos/3/1/30133/6900_sml.jpg)
6900
Specifications of 6900
54007928157
6900 CRIMPLOK CONN
80-6108-4525-9
80610845259
MF6900
Available stocks
Related parts for 6900
6900 Summary of contents
Page 1
... Multimode SC ™ Crimplok Connector Technical Report June 1999 80-6110-1444-2 1 ...
Page 2
... The connector is then ready for use. 2.0 Test Program The purpose of the test program is to assess the long-term performance of the 3M SC Crimplok fiber optic connector product. A series of optical, environmental and mechanical tests were conducted, which expose them to conditions more severe than those anticipated in actual use ...
Page 3
New Product Procedure: The plugs and couplings for pretest measurements were cleaned as described in section 1.7.4 of the TIA-568A. Measurements of loss and return loss at wavelengths of 850 nm and 1310 nm were performed at ambient conditions ...
Page 4
Temperature Life (Group 0) Procedure: Testing is performed on samples after exposure to the Cold Test. Measurements of loss and return loss at 850 nm and 1310 nm wavelengths are performed at the start and finish of test at ...
Page 5
... Testing was performed on samples subjected to the Flex Test. The connector - coupling is mounted onto the swingarm of the 3M Flex Tester and the swingarm is locked in the 0° position (3.3 lbs.) load is attached to the cable 25 cm from the pivot point. The weight is rotated about the cable axis 2.5 revolutions in one direction, reversed for 5 revolutions, and reversed for 5 more revolutions for a total of 10 cycles ...
Page 6
Cable Retention Procedure: Testing was performed on samples subjected to Twist Test. A coupling was secured to the traversing stage of an Instron tensile tester. At 0.3 m from the coupling/connector, the cable was secured to the stationary base ...
Page 7
... After completion of the Connector Durability Test, the 10 samples from group 2 were subjected to a connector intermatability. One side of each conectorized samples was removed and mated Epoxy factory mount SC connector, then removed and inserted 10 times. Cleaning and measurements were performed after every insertion. ...
Page 8
... Warranty and Limited Remedy This product will be free from defects in material and manufacture for a period of one year from the date of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M’ ...