T0-3-8342/V/SVB MOELLER, T0-3-8342/V/SVB Datasheet

no-image

T0-3-8342/V/SVB

Manufacturer Part Number
T0-3-8342/V/SVB
Description
SWITCH, REAR, DOOR, 20A, 6POLE
Manufacturer
MOELLER
Series
T0r
Datasheet

Specifications of T0-3-8342/V/SVB

No. Of Poles
6
Contact Voltage Ac Max
690V
Contact Current Ac Max
20A
Svhc
No SVHC (18-Jun-2010)
Current Rating
20A
Power Rating
11kW
Switching Ac3 Power Max
6.5kW
Voltage
RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
T0-3-8342/V/SVB
Manufacturer:
MOELLER
Quantity:
6 000
Type: T0−3−8342/V/SVB
Article No.: 034128
Contact sequence
1
Ordering information
Design
Description
Main conducting paths No. of poles
Auxiliary contacts
Auxiliary contacts
Max. three−phase motor rating (per set
of 3 contacts) 50−60 Hz AC−3 400/415
V 50−60 Hz
Rated uninterrupted current
Note for table header
General
Standards
P
I
u
N/O
kW
M
B
A
Rear mounting
Without auxiliary contacts
6
0
0
11
20
According to IEC/EN 60204−1,
VDE 0113 Part 1; with red
rotary handle and yellow
locking collar, lockable in 0
position
IEC/EN 60947, VDE 0660,
IEC/EN 60204, CSA, UL

Related parts for T0-3-8342/V/SVB

T0-3-8342/V/SVB Summary of contents

Page 1

... Type: T0−3−8342/V/SVB Article No.: 034128 Ordering information Design Description Main conducting paths No. of poles Auxiliary contacts Auxiliary contacts Max. three−phase motor rating (per set of 3 contacts) 50−60 Hz AC−3 400/415 V 50−60 Hz Rated uninterrupted current Note for table header Contact sequence ...

Page 2

... Safe isolation to VDE 0106 Part 101 and Part 101/A1 between the contacts Switching angles Contact units Double−break contacts 2 Switch−disconnectors to IEC/EN 60947−3 Load−break switches to IEC/EN 60947−3 6 Operations × Operations/h 3000 Damp heat, constant, to IEC 60068−2−78; Damp heat, cyclical, to IEC 60068− ...

Page 3

... AC−3 motor load switch motor rating 230 V 230 V Star−delta 400 V 400 V Star−delta 500 V 500 V Star−delta 690 V 690 V Star−delta AC−23A Motor load switches (main switches maintenance switches) 230 V 400 V 500 V Rated operational current control switch AC−15 230 V 400 V ...

Page 4

... Quantity Quantity Quantity Quantity Fault < probability operations For mechanical shock resistance: T3.../I... >12g Applies to T0(3).../SVB: isolating characteristics to IEC/EN 60947 Ufor rated operational voltage up to 500 V AC Applies to rated uninterrupted current I contact: with T5−4−8344/I5 −5 , < 1 fault in 100000 of the u ...

Page 5

... Dimensions Explaination Dimensions Dimensions Characteristic curve 5 max For terminal capacity solid, stranded and flexible: T0(3), (6), (8)...: Maximum of 2 cross−section sizes difference admissible between 2 conductors T5(B)−...: Maximum of 1 cross−section size difference admissible between 2 conductors For type T8−3−8342/... the following applies: switching angle = 90° ...

Page 6

... Moeller GmbH, Hein−Moeller−Str. 7−11, D−53115 Bonn E−Mail: catalog@moeller.net, Internet: www.moeller.net, http://catalog.moeller.net Copyright 2006 by Moeller GmbH. Subject to modifications. HPL−C2006GB−INT V2.3 6 ...