Specifications of CV500BC101

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
120
Setting Data Links
First data link sta-
tus word
Area 1 Data link
Area 2 Data link
Setting item
Note a) The total number of words in data link send and receive areas
start word
Number of
words
Offset
start word
Number of
words
Offset
b) The following values must be satisfied for each node for the data
must not exceed 8,000 per node.
link area 1 and area 2 so that the final word in the data link does
not go beyond the last word in the PLC memory area.
Set the first word to store data link status. An area of 16 words
is used.
IR Area:
LR Area:
DM Area: DM 0000 to DM 5984
EM Area: Banks 00 to 15, EM 0000 to EM 6128
*: When IR 000 is specified or when the default setting (
IR Area:
LR Area:
DM Area: DM 0000 to DM 5999
EM Area: Banks 00 to 15, EM 0000 to EM 6143
The same area cannot be set for both area 1 and area 2. Set
different areas.
Remote nodes: 0 to the number of source words
Local node:
The total number of words in area 1 and area 2 in each node
must not exceed 1,000.
The numbers of words in both area 1 and area 2 in each node
must not be set to 0.
Remote nodes: 0 to one less than number of source words
Local node:
This setting is not required if an offset is not used.
IR Area:
LR Area:
DM Area: DM 0000 to DM 5999
EM Area: Banks 00 to 15, EM 0000 to EM 6143
The same area cannot be set for both area 1 and area 2. Set
different areas.
Remote nodes: 0 to the number of source words
Local node:
Set the number of words to be transmitted.
The total number of words in area 1 and area 2 in each node
must not exceed 1,000.
The numbers of words in both area 1 and area 2 in each node
must not be set to 0.
Remote nodes: 0 to one less than number of source words
Local node:
This setting is not required if an offset is not used.
is left unchanged, the default first status word will be used.
Refer to 5-4 Checking Data Link Status for details.
(EM must be installed)
(EM must be installed)
(EM must be installed)
IR 001 to IR 220, IR 300 to IR 496 (*)
LR 00 to LR 48
IR 000 to IR 235, IR 300 to IR 511
LR 00 to LR 63
IR 000 to IR 235, IR 300 to IR 511
LR 00 to LR 63
Set the number of words to be received.
0 to 1,000
Set the number of words to be transmitted.
Set the offset for the data to be received.
Cannot be set.
Set the number of words to be received.
0 to 1,000
Set the offset for the data to be received.
Cannot be set.
Setting range
Section 5-2
––––
)