CV500CN224 Omron, CV500CN224 Datasheet - Page 6

no-image

CV500CN224

Manufacturer Part Number
CV500CN224
Description
Programmable Logic Controller
Manufacturer
Omron
Datasheet

Specifications of CV500CN224

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Product Specifications
External I/O
External I/O
Feed
operations
operations
Axis
Axis
control
control
Task
Task
program
program
management
Saving
Saving
program
program
data
Program and position data
automatic download function
Item
Peripheral device
Encoder
MPG/sync
encoder
Servo Drive
relationships
relationships
Individual axis
control
control
Others
Rapid feed rate
Interpolation feed
rate
Rapid feed
override
Interpolation feed
override
Jog feed override
Zone settings
Backlash
correction
In-position zone
Position loop
gain
Feedforward gain
Number of tasks
Number of
programs
Program capacity
Position data
capacity
Number of
registers
Subroutine
nesting
MC Module
External
peripheral
devices
Teaching Box (1 only)
Line receiver inputs:
For two axes
(500 kp/s before multiplication)
Line driver output-type MPG/sync encoder: 1
500 kp/s max. (before multiplication)
The following signals are each provided for two
axes:
Inputs:
Outputs: Drive alarm reset signals
The following signals are each provided for two
axes:
Input:
General inputs: 4 pts. (interrupt inputs)
General outputs: 4 pts. (brake signal outputs)
Example: 36.86 m/min
Conditions
Conditions
Encoder resolution: 2,048 p/r
Motor speed: 4,500 r/m
Control unit: 0.001 mm/pulse
0.1% to 100.0% (Setting unit: 0.1%)
0.1% to 199.9% (Setting unit: 0.1%)
0.1% to 100.0% (Setting unit: 0.1%)
Up to 8 zones/axis can be set.
Can be set from 0 to 10,000 pulses.
Can be set from 0 to 10,000 pulses.
1 to 250 (1/s)
0% to 100%
2 max. (program execution units)
When 1 task is used:
When 2 tasks are used:
When 1 task is used:
When 2 tasks are used:
The maximum number of blocks in a single
program is 800.
2,000 positions max. (total for all axes)
32 (Mainly used for specifying position data numbers.)
5 levels max.
Backed up by flash memory.
CX-Motion can be used to save data to a floppy disk or the hard disk at the personal computer.
When the operation number (program or position data) is specified by an IOWR instruction from the
CPU Unit, CX-Motion recognizes it and downloads the program or position data to the MC Module.
Drive alarm signals
High-speed reference voltage outputs (±10 V)
Operation command outputs
SEN signals (for absolute encoder)
CCW limit inputs
CW limit inputs
Origin proximity inputs
Emergency stop inputs
2,000 blocks
1,000 blocks/task
100
50
Specifications
Line receiver inputs:
For four axes
(500 kp/s before multiplication)
The following signals are each provided for four
axes:
The following signals are each provided for four
axes:
4 max. (program execution units)
When 1 task is used:
When 2 tasks are used:
When 3 task are used:
When 4 tasks are used:
When 1 task is used:
When 2 tasks are used:
When 3 task are used:
When 4 tasks are used:
The maximum number of blocks in a single
program is 800.
Motion Control Modules
2,000 blocks
1,000 blocks/task
666 blocks/task
500 blocks/task
100
50
33
25
5