Specifications of 170BNO67100
Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
- Current page: 86 of 108
- Download datasheet (6Mb)
Functions
86
(continued)
Advantys
Solution
Configuration and debugging software
For applications requiring short response times (< 3 ms), the Advantys STB
Distributed I/O Solution allows you to create reflex functions using the configuration
and debugging software. The reflex functions work directly at the level of the island
output modules, so that they are not taken into account or processed by the island's
master device. These reflex functions can be associated with “priority” I/O modules
to ensure reliable response times.
An Advantys STB island can call up to 10 reflex functions. These functions are
created from blocks whose inputs are activated by digital or analog input channels
and whose results activate a digital or analog output channel. You can nest two
reflex functions.
Various types of function blocks are available:
Documentation: A “Reflex actions” document is supplied on the CD-ROM
STB SUS 8800 and on our website www.us.telemecanique.com.
Functions
Reflex Functions Editor
Reflex types and function blocks
Boolean logic function blocks: XOR block,
AND blocks with 3 inputs and 1 output
Rising/falling edge counting function
blocks: on rising or falling edge, from
0 to 65,535
Digital Latch function blocks: on state
0 or 1 or on rising or falling edge, memorize
state 0 or 1
(continued)
digital latch on falling
falling-edge counter
counter preset
AND
edge
™
STB Distributed I/O
Timer/monostable blocks: when working,
when idle, upon activation, and upon
deactivation
Compare function blocks on signed
integers (-32,768 to 32,767): i <, i >, < i >,
i < and i >
Analog Latch function blocks: on state
0 or 1 or on rising or falling edge, memorize
the signed integer (0 to 65,535) or unsigned
integer (-32,768 to 32,767)
threshold 1 +/-
time unit x terminal count
outside-the-window compare
high-level analog latch
delay-to-start timer
Δ
threshold 2 +/-
Δ
0
Related parts for 170BNO67100
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
TRANSFORMR AUTO 115-230VAC 200VA
Manufacturer:
Hammond Manufacturing
Datasheet:
Part Number:
Description:
Pushbutton, Non-Illum'd Red "STOP", Momentary, 1NO-1NC, Square 30mm, 10A, 600V
Manufacturer:
SQUARE D
Datasheet:
Part Number:
Description:
KITS,TWIDO? PROGRAMMABLE CONTROLLERS,KITS,TWIDOPACK STARTER KIT - ADVANCED LEVEL,PROGRAMMABLE CONTROLLERS,TWIDO? PROGRAMMABLE CONTROLLERS ,SQUARE D
Manufacturer:
SQUARE D
Part Number:
Description:
LAMPS,INDICATOR,STACKABLE,LAMPS, STACKABLE INDICATOR,VISUAL INDICATING SIGNALS,XVB SERIES INDICATING BANKS ,SQUARE D
Manufacturer:
SQUARE D
Part Number:
Description:
LAMPS,INDICATOR,STACKABLE,LAMPS, STACKABLE INDICATOR,VISUAL INDICATING SIGNALS,XVB SERIES INDICATING BANKS ,SQUARE D
Manufacturer:
SQUARE D
Datasheet:
Part Number:
Description:
CB ACCESSORY, UNDERVOLTAGE TRIP 48V DC
Manufacturer:
SQUARE D
Datasheet: