95/00387989 JUMO, 95/00387989 Datasheet - Page 2

INDICATOR, DISPLAY, DI32

95/00387989

Manufacturer Part Number
95/00387989
Description
INDICATOR, DISPLAY, DI32
Manufacturer
JUMO
Datasheet

Specifications of 95/00387989

Thermocouple Type
L, J, U, T, K, N, S, R, B, D, C
Operating Temperature Max
55°C
Operating Temperature Min
0°C
Output Voltage Max
230VAC
External Depth
83mm
External Length / Height
48mm
Technical data
Input for thermocouple
Input for resistance thermometer
Input for resistance transmitter
Input for potentiometer
09.01/00383037
M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany
Designation
Fe-Con
Fe-Con
Cu-Con
Cu-Con
NiCr-Ni
NiCr-Con
NiCrSi-NiSi
Pt10Rh-Pt
Pt13Rh-Pt
Pt30Rh-Pt6Rh B
W3Re-W25Re D
W5Re-W26Re C
Sampling rate
Cold junction
Decimal place
Designation
Pt100
Pt100
Pt1000
Pt1000
KTY11-6
Sensor lead resistance
Measuring current
Lead compensation
Decimal place
Designation
0 — 4kΩ
Sensor lead resistance
Measuring current
Decimal place
Designation
0 — 4kΩ
0 — 4kΩ
Sensor lead resistance
Measuring current
Lead compensation
Decimal place
= factory setting
U
T
K
E
N
S
R
L
J
EN 60 751
EN 60 751
EN 60 751
EN 60 751
EN 60 584
EN 60 584
EN 60 584
EN 60 584
EN 60 584
EN 60 584
EN 60 584
EN 60 584
Range limits
Connection circuit
2-wire
3-wire
2-wire
3-wire
2-wire
not required for 3-wire circuit. For 2-wire circuit, lead compensation can be implemented in
software through actual-value correction.
Range
0 — 4kΩ
Connection circuit
2-wire
3-wire
not required for 3-wire circuit. For 2-wire circuit, lead compensation can be implemented in
software through actual-value correction.
-200
-210
-200
-270
-270
-270
-270
-50
-50
0 — 2320°C
0 — 1820°C
0 — 2495°C
+1200°C
+1372°C
+1000°C
+1768°C
+ 900°C
+ 600°C
+ 400°C
+1300°C
+1768°C
25µA or 250µA (depending on size of resistance)
20Ω max. per lead in 2-wire and 3-wire circuit
20Ω max. per lead in 2-wire and 3-wire circuit
Range
Pt100 internal or external constant (CJT)
-200
-200
-200
-200
-200
-150
-100
+300
Range
-200 +850°C
-200 +850°C
-200 +850°C
-200 +850°C
Range
0 — 4kΩ
0 — 4kΩ
-50 +150°C
0 — 1768°C
0 — 1768°C
0 — 2495°C
0 — 2320°C
4 measurements per second
+1200°C
+ 400°C
+1372°C
+1000°C
+1820°C
+ 900°C
+ 600°C
+1300°C
Measurement accuracy
≤0.5%
20Ω max. per lead
configurable
configurable
configurable
configurable
250µA
250µA
Measurement
accuracy in
range
≤0.4%
≤0.4%
≤0.4%
≤0.4%
≤0.4%
≤0.4%
≤0.4%
≤0.4%
≤0.4%
≤0.4%
≤0.4%
≤0.4%
Measurement
accuracy
≤0.1%
≤0.1%
≤0.1%
≤0.1%
≤1.0%
Measurement
accuracy
≤0.4%
≤0.4%
Data Sheet 95.1530
Ambient
temperature error
50 ppm/°C
Ambient
temperature
error
100 ppm/°C
100 ppm/°C
100 ppm/°C
100 ppm/°C
100 ppm/°C
100 ppm/°C
100 ppm/°C
100 ppm/°C
100 ppm/°C
100 ppm/°C
100 ppm/°C
100 ppm/°C
Ambient
temperature error
50 ppm/°C
50 ppm/°C
50 ppm/°C
50 ppm/°C
50 ppm/°C
Ambient
temperature error
50 ppm/°C
50 ppm/°C