E5EK-TAA2500ACDC24 Omron, E5EK-TAA2500ACDC24 Datasheet - Page 5

Controllers, Process

E5EK-TAA2500ACDC24

Manufacturer Part Number
E5EK-TAA2500ACDC24
Description
Controllers, Process
Manufacturer
Omron
Datasheet

Specifications of E5EK-TAA2500ACDC24

Operating Temperature Max
55°C
Operating Temperature Min
-10°C
Temperature Accuracy ±
0.3%
Output Type
Relay
Thermocouple Type
J, K, T, E, L, U, N, R, S, B, W, PLII
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Characteristics Table
J Option Board Ratings and Characteristics
Note: Event input is used for switching the target value, run or stop command, or automatic and manual mode with an external signal
J Current Transformer Ratings
Note: 1. Use within the max. heater current rating of controller table shown below.
J Heater Burnout Alarm
Note: 1. The heater burnout alarm is always OFF if the alarm is set to 0.0 A and always ON if the alarm is set to 50.0 A.
EMC
Approved standards
E53-AKB
E53-AK01
E53-AK02
E53-AK03
E53-AKF
Max. continuous heater current
Dielectric strength
Vibration resistance
Weight
Accessories
Max. heater current
Heater current value display accuracy ±5% FS±1 digit max.
Heater burnout alarm setting range
Min. detection ON time
2. No heater burnout detection or heater current value measurement is possible if the control output (heat) is ON for less
Model
input.
than 190 ms.
Model
Event input
Communications
Transfer output
-- continued from previous page
Description
RS-232C
RS-422
RS-485
E54-CT1
50 amps
1,000 VAC for 1 min
50 Hz, 98 m/s
Approx. 11.5 g
----
Single-phase 50 A AC
0.1 to 49.9 A (in units of 0.1 A) (See Note 1)
190 ms (See Note 2)
Emission Enclosure:
Emission AC Mains:
Immunity ESD:
Immunity RF-interference:
Immunity Conducted Disturbance: ENV50141: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst:
UL1092, CSA22.2 No. 14, CSA22.2 No. 1010-1
Conforms to EN50081-2, EN50082-2, EN61010-1 (IEC1010-1)
Conforms to VDE0106/part 100 (Finger Protection), when the separately-ordered terminal
cover is mounted.
Ramp/Soak Process Controller
Contact input:
ON: 1 kΩ max., OFF: 100 kΩ min.
No-contact input:
ON: residual voltage 1.5 V max., OFF: leakage current 0.1 mA max.
Transmission method: Half-duplex
S
Synchronization method: Start-stop synchronization (asynchronous method)
Baud rate: 1 2/2 4/4 8/9 6/19 2 kbps
Baud rate: 1.2/2.4/4.8/9.6/19.2 kbps
4 to 20 mA: Permissible load impedance: 600 Ω max.;
Resolution: approx. 2,600 steps
2
(10G)
h
i
i
h d S
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61000-4-2: 4 kV contact discharge
(level 2) 8 kV air discharge (level 3)
ENV50140: 10 V/m (amplitude modulated,
80 MHz to 1 GHz) (level 3)
10 V/m (pulse modulated, 900 MHz)
EN61000-4-4: 2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
p
Specifications
E5AK- -T/E5EK- -T
E54-CT3
120 amps (See Note 1)
Approx. 50 g
Armature: 2; Plug: 2
h
i
i
(
h
5
h d)