D4N-1120 Omron, D4N-1120 Datasheet - Page 6

LIMIT SWITCH, ROLLER LEVER

D4N-1120

Manufacturer Part Number
D4N-1120
Description
LIMIT SWITCH, ROLLER LEVER
Manufacturer
Omron
Series
D4Nr
Datasheets

Specifications of D4N-1120

Operating Force Max
5N
Contact Voltage Ac Max
240V
Contact Voltage Dc Max
250V
Contact Current Ac Max
10A
Contact Current Dc Max
2.5A
Switch Terminals
Screw
Svhc
No SVHC (15-Dec-2010)
Actuator
RoHS Compliant
Actuator Style
Roller Lever
Circuit
DPST (1-NO, 1-NC)
Switch Function
On-Mom, Off-Mom
Contact Rating @ Voltage
10A @ 120VAC
Actuator Type
Lever, Roller
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Operating Force
510gf
Rohs Compliant
Yes
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Characteristics
Note: 1. The above values are initial values.
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for
*2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details, consult your
*3. Do not pass the 3 A, 250 VAC load through more than 2 circuits.
*4. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the actual
*5. The mechanical durability of fork lever lock models is 10,000,000 operations min.
Degree of protection *1
Durability *2
Operating speed
Operating frequency
Contact resistance
Minimum applicable load *4
Rated insulation voltage (U
Rated frequency
Protection against electric shock
Pollution degree (operating environment)
Impulse withstand
voltage
(EN60947-5-1)
Insulation resistance
Contact gap
Vibration resistance
Shock resistance
Conditional short-circuit current
Conventional free air thermal current (I
Ambient operating temperature
Ambient operating humidity
Weight
the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do not use the D4N
in places where foreign material such as dust, dirt, oil, water, or chemicals may penetrate through the head. Otherwise, accelerated wear,
Switch damage or malfunctioning may occur.
OMRON representative.
load beforehand.
2. Once a contact has been used to switch a standard load, it cannot be used for a load of a smaller capacity.
Doing so may result in roughening of the contact surface and contact reliability may be lost.
Mechanical
Electrical
Between terminals of
same polarity
Between terminals of
different polarity
Between each terminal
and non-current carrying
metallic parts
Malfunction
Destruction
Malfunction
i
)
th
)
IP67 (EN60947-5-1)
15,000,000 operations min. *5
500,000 operations min. (3 A resistive load at 250 VAC) *3
300,000 operations min. (10 A resistive load at 250 VAC)
1 to 500 mm/s (D4N-1120)
30 operations/minute max.
25 mΩ max.
1 mA resistive load at 5 VDC (N-level reference value)
300 V
50/60 Hz
Class II (double insulation)
3 (EN60947-5-1)
2.5 kV
4 kV
6 kV
100 MΩ min.
Snap-action: 2 × 0.5 mm min.
Slow-action: 2 × 2 mm min.
10 to 55 Hz, 0.75 mm single amplitude
1,000 m/s
300 m/s
100 A (EN60947-5-1)
10 A (EN60947-5-1)
−30 to 70°C (with no icing)
95% max.
Approx. 82 g (D4N-1120)
Approx. 99 g (D4N-5120)
2
min.
2
min.
D4N
6

Related parts for D4N-1120