D4N3262 Omron, D4N3262 Datasheet

LIMIT SWITCH, ROLLER LEVER, 2NC

D4N3262

Manufacturer Part Number
D4N3262
Description
LIMIT SWITCH, ROLLER LEVER, 2NC
Manufacturer
Omron
Type
Limit Switchr
Datasheets

Specifications of D4N3262

Actuator Style
Roller Lever
Operating Force Max
5N
Contact Voltage Ac Max
240V
Contact Voltage Dc Max
250V
Contact Current Ac Max
10A
Contact Current Dc Max
2.5A
Switch Terminals
Screw
Switch Function Configuration
N.C.
Current Rating (max)
3A
Operating Temp Range
-30C to 70C
Lead Free Status / RoHS Status
na
Upgraded Safety Limit Switches Based
on the Popular D4D, Providing a Full
Lineup Conforming to International
Standards
Model Number Structure
Model Number Legend
1. Conduit size
2. Built-in Switch
D4N-@@@@
• Lineup includes three contact models with 2NC/1NO and 3NC
• M12-connector models are available, saving on labor and
• Standardized gold-clad contacts provide high contact reliability.
• Conforms to EN115, EN81-1, and EN81-2 (slow-action models
• Lineup includes both slow-action and snap-action models with
• Certified standards: UL, EN (TÜV), and CCC
Safety Limit Switch
D4N
contact forms in addition to the previous contact forms 1NC/
1NO, and 2NC. Models with MBB contacts are also available.
simplifying replacement.
Can be used with both standard loads and microloads.
only).
Zb contacts.
1: Pg13.5 (1-conduit)
2: G1/2 (1-conduit)
3: 1/2-14NPT (1-conduit)
4: M20 (1-conduit)
5: Pg13.5 (2-conduit)
6: G1/2 (2-conduit)
7: 1/2-14NPT (2-conduit)
8: M20 (2-conduit)
9: M12 connector (1-conduit)
1: 1NC/1NO (snap-action)
2: 2NC (snap-action)
A: 1NC/1NO (slow-action)
B: 2NC (slow-action)
C: 2NC/1NO (slow-action)
D: 3NC (slow-action)
E: 1NC/1NO (MBB contact) (slow-action)
F: 2NC/1NO (MBB contact) (slow-action)
Be sure to read the “Safety Precautions” on page 18
and the “Precautions for All Safety Limit Switches” .
1 2
3
3. Head and Actuator
20: Roller lever (resin lever, resin roller)
22: Roller lever (metal lever, resin roller)
25: Roller lever (metal lever, metal roller)
26: Roller lever (metal lever, bearing roller)
2G: Adjustable roller lever, form lock (metal lever, resin roller)
2H: Adjustable roller lever, form lock (metal lever, rubber roller)
31: Top Plunger
32: Top Roller Plunger
62: One-way roller arm lever (horizontal)
72: One-way roller arm lever (vertical)
80: Cat whisker
87: Plastic rod
RE: Fork lever lock (right operation)
LE: Fork lever lock (left operation)
Note: Contact your sales representative for details on models
with safety standard certification.
CSM_D4N_DS_E_3_1
1

Related parts for D4N3262

D4N3262 Summary of contents

Page 1

Safety Limit Switch D4N Upgraded Safety Limit Switches Based on the Popular D4D, Providing a Full Lineup Conforming to International Standards • Lineup includes three contact models with 2NC/1NO and 3NC contact forms in addition to the previous contact forms ...

Page 2

... M20 Note recommended that M20 be used for Switches to be exported to Europe and 1/2-14NPT be used for Switches to be exported to North American countries. Consult with your OMRON representative when ordering any models that are not listed in this table. Built-in switch mechanism 1NC/1NO ...

Page 3

Switches with Three Contacts and MBB Contacts (with Direct Opening Mechanism) Actuator Conduit size Roller lever (resin Pg13.5 lever, resin roller) G1/2 1-conduit 1/2-14NPT M20 M12 connector Pg13.5 2-conduit G1/2 M20 Roller lever (metal Pg13.5 lever, resin roller) G1/2 1-conduit ...

Page 4

General-purpose Switches with Two Contacts Actuator Conduit size Fork lever lock G1/2 (right operation) 1-conduit 1/2-14NPT M20 G1/2 2-conduit M20 Fork lever lock (left G1/2 operation) 1-conduit 1/2-14NPT M20 G1/2 2-conduit M20 Cat whisker G1/2 1-conduit 1/2-14NPT M20 G1/2 2-conduit ...

Page 5

... UL *2 UL508, CSA C22.2 No.14 E76675 CQC (CCC) *3 GB14048.5 *1. Consult your OMRON representative for details. *2. Certification for CSA C22.2 No authorized by the UL mark. *3. Ask your OMRON representative for information on certified models. Certified Standard Ratings TÜV (EN60947-5-1), CCC (GB14048.5) Item Rated operating current (I ...

Page 6

... Switch damage or malfunctioning may occur. *2. The durability is for an ambient temperature 35°C and an ambient humidity of 40% to 70%. For more details, consult your OMRON representative. *3. Do not pass the 3 A, 250 VAC load through more than 2 circuits. *4. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the actual load beforehand ...

Page 7

Structure and Nomenclature Structure Safety-oriented Lever Setting (Form-lock construction) Grooves which engage the lever are cut in the lever and rotary shaft to prevent the lever from slipping against the rotary shaft. There are resin-lever and metal-lever types. Built-in Switch ...

Page 8

Contact Form Model Contact 1NC/1NO D4N-@1@ (Snap-action) D4N-@2@ 2NC (Snap-action) 1NC/1NO D4N-@A@ (Slow-action) D4N-@B@ 2NC (Slow-action) 2NC/1NO D4N-@C@ (Slow-action) D4N-@D@ 3NC (Slow-action) 1NC/1NO MBB * D4N-@E@ (Slow-action) 2NC/1NO MBB * D4N-@F@ (Slow-action) Note: Terminals are numbered according to EN50013 and ...

Page 9

Dimensions and Operating Characteristics Switches 1-conduit Models Roller Lever (Resin Lever, Resin Roller) D4N-1@20 D4N-2@20 D4N-3@20 D4N-4@20 D4N-9@20 * 17.5 dia. × 6.8 resin roller 26R Resin lever 18 9 ±0.2 2.5 ± 0.1 20 ± 0 ± ...

Page 10

Models Plunger D4N-1@31 D4N-2@31 D4N-3@31 D4N-4@31 D4N-9@31 * ±0.1 25 Two, 3±0.05 dia. (31.5) holes 21.5 12 dia. 11 6-dia. resin plunger OP ±0.2 9 2.5 ± 0 ± 0.2 ± 0 2.15±0.05R mounting holes ...

Page 11

Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC) Model D4N-@131 D4N-@231 D4N-@B31 Operating characteristics D4N-@D31 Operating force OF max. 6.5 N Release force RF min. 1.5 N Pretravel PT max Overtravel OT min max. *1 Movement differential ...

Page 12

Models Adjustable Roller Lever, Form Lock (with Metal Lever, Resin Roller) D4N-1@2G D4N-2@2G D4N-3@2G D4N-4@2G D4N-9@2G * 17.5 dia. × 6.8 resin roller 20 to 66R 18 9 ± 0.2 2.5 47 ± 0.2 55 2.15±0.05R 20 ± 0.1 ...

Page 13

Models Fork Lever Lock (Right Operation) *2 D4N-1@RE D4N-2@RE D4N-3@RE D4N-4@RE Two, 17.5 dia. × 8 rubber rollers 90° 26R 18 9± 0.2 2.5 20± 0.1 47± 22± 0.2 0.1 55 2.15±0.05R mounting holes 22± 0.2 Conduit cap 31 ...

Page 14

Models Roller Lever (Resin Lever, Resin Roller) D4N-5@20 17.5 dia. × 6.8 D4N-6@20 resin roller D4N-8@20 26R Resin lever 5.4 2 ±0 ±0.1 2.15±0.05R ±0.1 25 dia. 40 mounting holes Conduit cap 42 ±0.2 (3) ...

Page 15

Models One-way Roller Arm Lever (Horizontal) Operating direction D4N-5@62 14.8 D4N-6@62 12 dia ±0.2 11 resin roller D4N-8@62 13.5 20R OP 23.3 5.4 2.5 ±0.2 19.5 ± 20 0.1 2.15±0.05R 22 ± 0.1 mounting holes 25 dia. ...

Page 16

Models Fork Lever Lock (Right Operation) *2 D4N-5@RE D4N-6@RE D4N-7@RE D4N-8@RE Two, 17.5 dia. × 8 rubber rollers 90° 26R 5.4 2.5 18 ± 0.2 9 21.5 ±0.1 20 ±0.2 39 2.15±0.05R 22 ±0.1 25 dia. mounting holes 40 ...

Page 17

Levers Refer to the following for the angles and positions of the watchdogs (source: EN50047.) Roller Lever Adjustable Roller Lever, Form Lock (D4N-@@20) (with Metal Lever, Resin Roller) (D4N-@@2G) (Reference Values) 40 ±2 10 min. 15 ±3 Dog Dog 40 ...

Page 18

Safety Precautions Refer to the “Precautions for All Switches” and “Precautions for All Safety Limit Switches”. !CAUTION Electric shock may occasionally occur. Do not use metal connectors or metal conduits. Precautions for Safe Use • Do not use the Switch ...

Page 19

... Tolerance ± Pin No. (Terminal No.) • Applicable socket: XS2F-D421 series (OMRON). • Refer to the Connector Catalog for details on socket pin numbers and lead wire colors. Socket Tightening (Connector Type) • Turn the socket connector screws by hand and tighten until no space remains between the socket and the plug. ...

Page 20

Recommended Connectors Use connectors with screws not exceeding 9 mm, otherwise the screws will protrude into the case interior, interfering with other components in the case. The connectors listed in the following table have connectors with thread sections not exceeding ...

Page 21

Production Discontinuation Following the release of the D4N, production of the D4D-N was discontinued. Date of Production Discontinuation Production of the D4D-N Series was discontinued as of the end of March 2006. Recommended Substitute Product Sales of the D4N series ...

Page 22

List of Recommended Substitute Products : The actuator on the D4D non-safety type. The D4N is recommended for safety applications (form lock type). Be sure to mount it correctly screws are recommended to comply with European ...

Page 23

General-purpose Limit Switches Discontinued Recommended product substitute product D4D-1121N D4N-112G D4D-2121N D4N-212G D4D-3121N D4N-312G D4D-5121N D4N-512G D4D-6121N D4N-612G D4D-1127N D4N-112H D4D-2127N D4N-212H D4D-3127N D4N-312H D4D-5127N D4N-512H D4D-6127N D4N-612H D4D-1180N D4N-4180 D4D-2180N D4N-2180 D4D-3180N D4N-3180 D4D-5180N D4N-8180 D4D-6180N D4N-6180 D4D-1187N D4N-4187 ...

Page 24

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...