HS6E-P44B03-G IDEC, HS6E-P44B03-G Datasheet - Page 16

SWITCH, SAFETY INTERLOCK, 2NC, 2A

HS6E-P44B03-G

Manufacturer Part Number
HS6E-P44B03-G
Description
SWITCH, SAFETY INTERLOCK, 2NC, 2A
Manufacturer
IDEC
Series
HS6Er
Datasheet

Specifications of HS6E-P44B03-G

Contact Voltage Ac Max
125V
Contact Voltage Dc Max
30V
Contact Current Ac Max
2A
Contact Current Dc Max
2A
Switch Terminals
Cable
Contact Configuration
SPST-NC / SPST-NC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
World-class compactness with three poles of contacts.
Types
Actuators
Note: Select an actuator that moves in the direction required by the
Contact Ratings
• Minimum applicable load (reference): 3V AC/DC, 5mA
∗ Ratings approved by safety agencies
16
• World’s smallest switch: 30 × 30 × 78 mm
• Dual contacts and monitor contacts achieve the highest safety
• Two actuator entry slots provide flexibility for installation options.
• Integral cable design minimizes wiring, preventing wiring
• Can be mounted in two directions.
• Degree of protection (contacts): IP67 (IEC 60529)
• NC contacts are direct opening action (IEC/EN 60947-5-1).
• Proprietary actuators prevent unauthorized opening of the
1NC-1NO
2NC
2NC-1NO
3NC
Straight
Right-angle
Horizontal/vertical Angle Adjustable
(for hinged doors) (Note)
Rated Insulation Voltage (Ui)
Rated Current (Ith)
Rated Voltage (Ue) ∗
Contact Configuration Cable Length
Current
C300: AC-15, 0.75A/240V
Q300: DC-13, 0.27A/250V
category (ISO 13849-1, EN 954-1)
mistakes.
Housing allows drainage.
contacts (ISO14119, EN1088).
Rated
(Ie) ∗
33
31
21
31
21
31
11
11
11
11
HS6B
hinged door and interlock switch (see pages 17 and 18).
Zb
Zb
Zb
Zb
AC
DC
Description
Resistive load (AC-12)
Inductive Load (AC-15)
Resistive load (DC-12)
Inductive Load (DC-13)
12
34
12
32
12
22
32
12
22
32
1m
3m
5m
1m
3m
5m
1m
3m
5m
1m
3m
5m
Subminiature Interlock Switches
Opening
(Package quantity: 1)
Action
2.5A
2.3A
Direct
30V
(Package quantity: 1)
HS6B-11B01
HS6B-11B03
HS6B-11B05
HS6B-02B01
HS6B-02B03
HS6B-02B05
HS6B-12B01
HS6B-12B03
HS6B-12B05
HS6B-03B01
HS6B-03B03
HS6B-03B05
HS9Z-A61
HS9Z-A62
HS9Z-A65
HS9Z-A66
Type No.
Type No.
Insulation
0.55A
Double
300V
125V
2.5A
2.5A
1.5A
1.1A
0.75A
0.55A
0.27A
250V
1.5A
Specifications
Applicable Standards
Applicable Directive
Operating
Temperature
Relative Humidity
Storage Temperature
Pollution Degree
Impulse Withstand
Voltage
Insulation Resistance
(500V DC megger)
Contact Resistance
Electric Shock
Protection Class
Degree of Protection
Shock Resistance
Vibration Resistance
Actuator Operating
Speed
Direct Opening Travel 8 mm minimum
Direct Opening Force 60N minimum
Operating Frequency
Mechanical Durability 1,000,000 operations minimum (GS-ET-15)
Electrical Durability
Conditional
Short-circuit Current
Housing Color
Cable
Weight (approx.)
• Vertical/horizontal Angle
Adjustable Actuator (for
hinged door)
UL508 (UL listed)
CSA C22.2, No. 14 (c-UL listed)
ISO 14119
EN 1088
IEC 60947-5-1
EN 60947-5-1 (DEMKO approval)
GS-ET-15 (BG approval)
IEC 60204-1/ EN 60204-1
(applicable standards for use)
73/23/EEC (Low Voltage Directive)
–25 to +70°C (no freezing)
45 to 85% (no condensation)
–40 to +80°C (no freezing)
3
4 kV
Between live and dead metal parts:
Between terminals of different poles:
300 mΩ maximum (initial value, 1m cable)
500 mΩ maximum (initial value, 3m cable)
700 mΩ maximum (initial value, 5m cable)
Class II (IEC 61140)
IP67 (IEC 60529)
Operating extremes: 300 m/s
Damage limits:
Operating extremes:
Damage limits:
0.05 to 1.0 m/s
1200 operations/h
100,000 operations minimum
(operating frequency 1200 operations/h,
load AC-12 250V/1.5A, DC-12 250V/0.2A)
50A (250V) (Use 250V/10A fast-blow fuse for short-
circuit protection.)
Black
UL2464 No. 20 AWG (6-core)
120g (HS6B-03B01)
100 MΩ minimum
100 MΩ minimum
5 to 55 Hz, amplitude 0.5 mm
30 Hz, amplitude 1.5 mm
• Straight Actuator
• Right-angle Actuator
(SUS304)
(SUS304)
1000 m/s
2
(30G)
2
(100G)
(07/03/12)

Related parts for HS6E-P44B03-G