No. Of Phases
Single Or Three
Power Rating
4kW
Current Rating
7A
Operating Temperature Range
-25°C To +50°C
Overload Adjustment Current Min
1A
Power Rating, 3-phase
4kW
Frame Size
Standard
34
34-80
AC Ratings
Table 34-120. AC Ratings
AC-1 Operation
AC-3 Operation
AC-4 Operation
AC-6A Operation
AC-6B Operation
Description
Conventional Free Air Thermal Current,
3-Pole, 50 – 60 Hz
Conventional Free Air Thermal Current,
1-Pole (I th )
Rated Operational Current, 50/60 Hz
in amperes
Rated power (P) in kilowatts
Rated Operational Current, 50/60 Hz
in amperes
Rated power (P) in kilowatts
Transformer Loads
Capacitor Loads
Individual compensation rated operational cur-
rent I e of three-phase capacitors in amperes
Maximum inrush current peak (x I e )
Component Lifesaving (Operations)
Maximum Operating Frequency (ops/hr)
Open
Enclosed
Open
Enclosed
220/230V
240V
380/400V
415V
440V
500V
660/690V
1000V
220/230V
240V
380/400V
415V
440V
500V
660/690V
1000V
220/230V
240V
380/400V
415V
440V
500V
660/690V
1000V
220/230V
240V
380/400V
415V
440V
500V
660/690V
1000V
Up to 525V
690V
At maximum permissible ambient temperature.
Example —
The transformer has a nominal current of 10A with an inrush current of 18 times the nominal current. So, the contactor must have an AC-3 current of
18/6 x 10A = 30A. Using an XTCE032C (32A AC-3) contactor is recommended.
at 40°C (I th )
at 50°C (I th )
at 55°C (I th )
at 60°C (I th )
IEC Contactors & Starters
XT IEC Power Control
Contactors and Starters
(I e )
(I e )
XTCE007B
22A
21A
21A
20A
18A
50A
45A
30
Values are application specific. Calculation is I e
7
7
7
7
7
5
4
2.2
2.2
3
4
4.5
3.5
3.5
5
5
5
5
5
4.5
4
1
1.5
2.2
2.3
2.4
2.5
2.9
For more information visit: www.eaton.com
XTCE009B
22A
21A
21A
20A
18A
50A
45A
30
9
9
9
9
9
7
5
2.5
3
4
5.5
5.5
4.5
4.5
6
6
6
6
6
5
4.5
1.5
1.6
2.5
2.8
3
2.8
3.6
transformer and I e Transformer is the nominal current.
XTCE012B
22A
21A
21A
20A
18A
50A
45A
12
12
12
12
12
10
30
7
3.5
4
5.5
7
7.5
7
6.5
7
7
7
7
7
6
5
2
2.2
3
3.4
3.6
3.5
4.4
See Page 34-48 for Capacitor Ratings
AC-3
XTCE015B
22A
21A
21A
20A
18A
50A
45A
15.5
15.5
15.5
15.5
15.5
12.5
30
9
4
4.6
7.5
8
8.4
7.5
7
7
7
7
7
6
5
2
2.2
3
3.4
3.6
3.5
4.4
= X / 6 * I e Transformer where X is the inrush current of the
XTCE018C
40A
38A
37A
35A
32A
88A
80A
18
18
18
18
18
18
12
10
10.5
12
11
10
10
10
10
10
10
30
5
5.5
7.5
8
2.5
3
4.5
5
5.5
6
6.5
XTCE025C
100A
30
45A
43A
42A
40A
36A
90A
25
25
25
25
25
25
15
11
14.5
15.5
17.5
14
13
13
13
13
13
13
10
7.5
8.5
3.5
4
6
6.5
7
8
8.5
XTCE032C
100A
30
45A
43A
42A
40A
36A
90A
32
32
32
32
32
32
18
10
11
15
19
20
23
17
15
15
15
15
15
15
12
10
CA08102001E
4
4.5
7
7.5
8
9