XTAE007B10A001 EATON CUTLER HAMMER, XTAE007B10A001 Datasheet - Page 181

IEC Non-Reversing Starter

XTAE007B10A001

Manufacturer Part Number
XTAE007B10A001
Description
IEC Non-Reversing Starter
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of XTAE007B10A001

No. Of Phases
Single Or Three
Power Rating
3.5kW
Current Rating
7A
Operating Temperature Range
-25°C To +50°C
Mounting Type
DIN Rail
Overload Adjustment Current Max
1A
Overload Adjustment Current Min
0.6A
Supply Voltage Max
120VAC
Frame Size
Standard
Wiring Diagrams
Fuseless Installation with XTPR
Backup Protection Diagram—XTPR…B
Time/Current Curves
Characteristics
The time/current
characteristic, the current
limiting characteristics and
the I
determined in accordance
with DIN VDE 0660 and IEC
60 947.
The tripping characteristic of
the inverse-time delayed
overload releases (thermal
overload releases or “a”
releases) for DC and AC with
a frequency of 0 to 400 Hz
also apply to the time/current
characteristic.
The characteristics apply to
the cold state. At operating
temperature, the tripping
times of the thermal releases
are reduced to approximately
25%.
Under normal operating
conditions, all three-poles of
the device must be loaded.
The three main conducting
paths must be connected in
series in order to protect
single-phase or DC loads.
With three-pole loading, the
maximum deviation in the
tripping time for 3 times the
setting current and upwards
is ±20% and thus in
accordance with DIN VDE
0165.
Back-up
protection
range
with XTPAXCL
Rated
short-circuit
breaking
capacity
range
2
t characteristics were
XTPR…B
415 Vac
XTPR…B
100
50
30
20
16
10
6
XTPR...B
Inherently
short-circuit-proof
0.16...
The tripping characteristics
for the instantaneous,
electromagnetic overcurrent
releases (short-circuit
releases or “n” releases) are
based on the rated current I
which is also the maximum
value of the setting range for
circuit breakers with
adjustable overload releases.
If the current is set to a lower
value, the tripping current of
the “n” release is increased
by a corresponding factor.
The characteristics of the
electromagnetic overcurrent
releases apply to frequencies
of 50/60 Hz. Appropriate
correction factors must be
used for lower frequencies
up to 16-2/3 Hz, for higher
frequencies up to 400 Hz and
for DC.
Time/current characteristics,
current limiting characteristics
and I
available on request.
2
t characteristics are
Volume 5—Motor Control and Protection CA08100006E—May 2011 www.eaton.com
1016 20 25
Rated
Current
n [A]
n
,
IEC Contactors and Starters
Backup Protection Diagram—XTPR…D
MMP Tripping Characteristics
XTPB, XTPR Frame B
XTPR Frame D
Back-up
protection
range
with XTPAXCL
Rated
short-circuit
breaking
capacity
range
200
200
2h
20
10
20
10
50
20
2h
20
10
20
10
50
20
40
40
5
2
5
5
2
5
2
5
5
2
1
2
1
1
2
1
XTPR…D
1.5 2
1.5 2
x Rated Operational Current
x Rated Operational Current
3
3
415 Vac
XTPR…D
4
4
XT IEC Power Control
XTPB, XTPR Frame B
6
6
8 10
8 10
100
XTPR Frame D
30
16
50
20
10
6
15 20
15 20
16...
XTPT
25
XTPR...D + XTPAXCL
XTPR…D
Rated
Current
30
30
n [A]
32
40
50
Rated
Current
n [A]
27.1
63
V5-T27-181