XTAE007B10TD001 EATON CUTLER HAMMER, XTAE007B10TD001 Datasheet - Page 184
XTAE007B10TD001
Manufacturer Part Number
XTAE007B10TD001
Description
IEC Non-Reversing Starter
Manufacturer
EATON CUTLER HAMMER
Datasheet
1.XTAE007B10A001.pdf
(240 pages)
Specifications of XTAE007B10TD001
No. Of Phases
Single Or Three
Power Rating
3.5kW
Current Rating
7A
Operating Temperature Range
-25°C To +50°C
Mounting Type
DIN Rail
Overload Adjustment Current Max
1A
Overload Adjustment Current Min
0.6A
Supply Voltage Max
24VDC
Frame Size
Standard
- Current page: 184 of 240
- Download datasheet (4Mb)
27.1
Global Use, IEC/EN 60947—XTPR…DC1 with Classification Type “1” and Type “2”
I
A
16
25
32
40
50
58
63
Ratings for Group Motor Applications
UL 508/CSA C22.2 No. 14—XTPB—Frame B, Manual Motor Protector with Thermal and Magnetic Trip
Catalog Number
XTPBP16BC1
XTPBP25BC1
XTPBP40BC1
XTPBP63BC1
XTPB001BC1
XTPB1P6BC1
XTPB2P5BC1
XTPB004BC1
XTPB6P3BC1
XTPB010BC1
XTPB012BC1
XTPB016BC1
XTPB020BC1
XTPB025BC1
Notes
V5-T27-184
u
N = Not required.
XTPR…BC1, XTPT, XTPM—Required back-up fuse if the short-circuit current exceeds the rated conditional short-circuit current (I
switching capacity of the motor protective circuit breaker to 100 kA.
No upstream protective device required, as it is the auto-protected range (100/150 kA—Frame B, 150 kA—Frame D).
IEC/EN 60947-4-1
22 kA 600 Vac.
230V
I
kA
150
150
50
50
50
50
50
q
Rated
Uninterrupted
Current—
I
12
16
20
25
0.16
0.25
0.4
0.63
1
1.6
2.5
4
6.3
10
I
kA
150
150
50
50
50
50
50
u
cu
(Amps)
Volume 5—Motor Control and Protection CA08100006E—May 2011 www.eaton.com
I
kA
25
25
25
25
25
25
25
IEC Contactors and Starters
XT IEC Power Control
cs
Fuse
A
N
N
100
100
100
160
160
FLA
Adjustment
Range/Overload
Release—
I
0.1–0.16
0.16–0.25
0.25–0.4
0.4–0.63
0.63–1
1–1.6
1.6–2.5
2.5–4
4–6.3
6.3–10
8–12
10–16
16–20
20–25
r
(Amps)
400V
I
kA
150
150
50
50
50
50
50
q
I
kA
150
150
50
50
50
50
50
cu
Short
Circuit
Release—
I
2.2
3.5
5.6
8.8
14
22
35
56
88
140
168
224
280
350
rm
(Amps)
I
kA
25
25
25
25
25
25
25
cs
Fuse
A
N
N
100
100
100
160
160
Maximum Protective Device for UL/CSA Group Protection
Maximum rms
Sym Current—
480V (kA)
50
50
50
50
50
50
50
50
50
30
10
10
10
10
440V
I
kA
45
45
45
45
45
45
45
q
I
kA
45
45
45
45
45
45
45
cu
w/Current
Limiter—
XTPAXCL
—
—
—
—
—
—
—
—
—
50
50
50
18
18
I
kA
25
25
25
25
25
25
25
cs
Fuse
A
100
100
100
100
100
160
160
Maximum Fuse
Rating (A)
600
600
600
600
600
600
600
600
600
600
150
150
150
150
cc
500V
I
kA
15
15
15
15
15
15
15
q
> I
q
); XTPB, XTPR…DC1—Fuse (A gG/gL) for enhancing the
I
kA
15
15
15
15
15
15
15
cu
w/Current
Limiter—
XTPAXCL
—
—
—
—
—
—
—
—
—
600
600
600
600
600
kA
I
cs
Fuse
A
100
100
100
100
100
160
160
Circuit Breaker
Maximum (A)
600
600
600
600
600
600
600
600
600
600
125
125
125
125
690V
I
kA
8
8
5
5
5
5
5
q
I
kA
8
8
5
5
5
5
5
cu
I
kA
2.5
2.5
2.5
2.5
2.5
2.5
2.5
cs
w/Current
Limiter—
XTPAXCL
—
—
—
—
—
—
—
—
—
600
600
600
600
600
Fuse
A
100
100
100
100
100
160
160
Related parts for XTAE007B10TD001
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
SUB FEED LUG BLOCK 150A CUTLER HAMMER TYPE BR LOADCENTER
Manufacturer:
EATON CUTLER HAMMER
Part Number:
Description:
Handle Tie Bar For (2) - 1 Pole Type BR Breakers
Manufacturer:
EATON CUTLER HAMMER
Part Number:
Description:
Type CL Breaker 25A/1Pole 120/240V 10K-Classified 1" Ckt Bkr
Manufacturer:
EATON CUTLER HAMMER