103H7123-5710 SANYO DENKI - SANMOTION, 103H7123-5710 Datasheet - Page 12

Stepper Motor

103H7123-5710

Manufacturer Part Number
103H7123-5710
Description
Stepper Motor
Manufacturer
SANYO DENKI - SANMOTION
Datasheet

Specifications of 103H7123-5710

No. Of Phases
Two
Inductance
7.5mH
Inertia
1.15oz-in
Peak Reflow Compatible (260 C)
No
Supply Voltage
24VDC
Current Rating
2A
Nema Size
23
Leaded Process Compatible
No
Torque Min
141.6in-oz
Shaft Configuration
Bipolar
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
11
2-phase STEPPING SYSTEMS
SET UP
The functions according to the specification can be selected with this Dip switch.
Confirm the ex-factory setting as follows.
Input pulse mode selection
This switch setting is only effective in pulse stream I/F
mode.
Low vibration and smooth operation is enabled even by the rough
resolution setting
This switch setting is only effective in pulse stream I/F mode.
For parallel I/F mode and serial I/F mode, this is usually a low
vibration operation.
Select the Motor winding current value when inputting the power down
signal.This switch setting is only effective in pulse stream I/F mode.
The operation mode is selected.
1
2
3
4
5
F / R
ON
OFF
e.g. 1 division, 2 division
LV
ON
OFF
PD
ON
OFF
I.SEL
OFF
ON
driving pulse will be carried out inside the Driver. Therefore, the Motor
movement delays for the time of 3.2ms pulse per input pulse. Note that
depending upon the combined Motor, load,driving profile and etc, it may
take a while until the shaft is adjusted when the Motor stops.
I/F mode and serial I/F mode there is no delay
PD function
is enabled by PD input signal ON
Output signal connector
the other current settings except for alarms. The operational status may
not be maintained such as power swing due to output torque drop or
lower operation due to Motor current OFF
attention to the input timing of the power down signal in addition that
the security device should be installed to the machine.
By turning on the EORG, excitation phase when power OFF is saved.
Change the operation mode selection switch after cutting off the driver
s power supply.
When LV select is ON
Input mode select
Low vibration mode select
Power down select
Excitation select
,
Specification
For pulse stream I/F mode
Function Select Dip Switch
6
Operation mode selection
Input pulse mode
1 input mode
2 input mode
Operation
Low vibration operation
Micro step operation
Motor winding current
Current value by rotary switch STP
0A
S.SEL
OFF
ON
the setting selected by PD of the function select dip switch
Power OFF
Operation mode
Pulse stream I/F mode
Parallel I/F mode
Serial I/F mode
low vibration mode
CK,U/D
CW,CCW
CN2
EORG
F/R
.
PD
. Power down signal input is prior to all
built-in photo coupler ON
LV
unexcited Motor
, operational process of
I.SEL, S.SEL
Power Low
1
2
3
4
5
6
F/R
LV
PD
EORG
I. SEL
S. SEL
OFF
of Input/
. Pay extra
In parallel
ON
OFF
OFF
OFF
OFF
OFF
OFF
2 input mode (CW/CCW pulse)
Micro step operation
Power OFF
Phase origin excitation
Pulse stream I/F mode
The communication speed of serial communication is
set.
Switch
F/R
LV
PD
The setting change after the power supply is turned on is invalid.
It does not function as a F/R, LV, and PD.
The communication speed of pulse stream I/F mode is fixed at 9600bps.
For parallel I/F mode or serial I/F mode
Set value
OFF
ON
OFF
ON
OFF
ON
9,600
Communication speed(bps)
19,200
38,400
115,200

Related parts for 103H7123-5710