PAXCDC30 Red Lion Controls, PAXCDC30 Datasheet - Page 30
PAXCDC30
Manufacturer Part Number
PAXCDC30
Description
DeviceNet Communications Network Interface Card
Manufacturer
Red Lion Controls
Specifications of PAXCDC30
Accessory Type
DeviceNet Communications Network Interface Card
Brand/series
PAX Series
Card Type
DeviceNet Communications Card
Standards
cULus Listed, CSA Certified and CE Marked
Voltage, Working
50 V
Pax Label Kit
189 Different Engineering Units, Labels Inserted Inside the Unit
For Use With
Red Lion PAX Digital Input Panel Meters
Lead Free Status / RoHS Status
na
PARAMETER VALUE CHART
PAX Model Number
* See Module 2, Exchanging Parameter Lists, for details on programming this value.
Shaded areas are model dependent.
Shaded areas are model dependent.
DISPLAY
DISPLAY
DISPLAY
Counter A & B Input Parameters - PAXC & I only
User Input and Function Key Parameters
Display and Program Lockout Parameters
COUNTER A OPERATING MODE
COUNTER A RESET ACTION
COUNTER A DECIMAL POSITION
COUNTER A SCALE FACTOR (A)
COUNTER A SCALE FACTOR (B) *
COUNTER A SCALE MULTIPLIER
COUNTER A COUNT LOAD VALUE (A)
COUNTER A COUNT LOAD VALUE (B)*
COUNTER A RESET POWER-UP
PRESCALER OUTPUT ENABLE
PRESCALER SCALE VALUE
COUNTER B OPERATING MODE
COUNTER B RESET ACTION
COUNTER B DECIMAL POSITION
COUNTER B SCALE FACTOR (A)
COUNTER B SCALE FACTOR (B)*
COUNTER B SCALE MULTIPLIER
COUNTER B COUNT LOAD VALUE (A)
COUNTER B COUNT LOAD VALUE (B)*
COUNTER B RESET POWER-UP
COUNTER A DISPLAY LOCK-OUT
COUNTER B DISPLAY LOCK-OUT
COUNTER C DISPLAY LOCK-OUT
RATE DISPLAY LOCK-OUT
MAX DISPLAY LOCK-OUT
MIN DISPLAY LOCK-OUT
SETPOINT 1 ACCESS LOCK-OUT
SETPOINT 2 ACCESS LOCK-OUT
SETPOINT 3 ACCESS LOCK-OUT
SETPOINT 4 ACCESS LOCK-OUT
COUNT LOAD A ACCESS
COUNT LOAD B ACCESS
COUNT LOAD C ACCESS
SCALE FACTOR A ACCESS
SCALE FACTOR B ACCESS
SCALE FACTOR C ACCESS
SECURITY CODE
USER INPUT 1
USER INPUT 2
USER INPUT 3
FUNCTION KEY 1
FUNCTION KEY 2
RESET KEY
2nd FUNCTION KEY 1
2nd FUNCTION KEY 2
PARAMETER
PARAMETER
PARAMETER
_________
FACTORY
SETTING
FACTORY
SETTING
FACTORY
SETTING
USER SETTING
USER SETTING
USER SETTING
Programmer ________________ Date ________
Meter# _____________ Security Code __________
30
Shaded areas are model dependent.
* See Module 2, Exchanging Parameter Lists, for details on programming this value.
DISPLAY
DISPLAY
Rate Input Parameters - PAXI & R only
COUNTER C OPERATING MODE
COUNTER C RESET ACTION
COUNTER C DECIMAL POSITION
COUNTER C SCALE FACTOR (A)
COUNTER C SCALE FACTOR (B)*
COUNTER C SCALE MULTIPLIER
COUNTER C COUNT LOAD VALUE (A)
COUNTER C COUNT LOAD VALUE (B)*
COUNTER C RESET POWER-UP
Counter C Input Parameters - PAXC & I only
RATE ASSIGNMENT
LOW UPDATE TIME
HIGH UPDATE TIME
RATE DECIMAL POINT
LINEARIZER SEGMENTS
SCALING PT. 1 - DISPLAY VALUE
SCALING PT. 1 - INPUT VALUE
SCALING PT. 2 - DISPLAY VALUE
SCALING PT. 2 - INPUT VALUE
SCALING PT. 3 - DISPLAY VALUE
SCALING PT. 3 - INPUT VALUE
SCALING PT. 4 - DISPLAY VALUE
SCALING PT. 4 - INPUT VALUE
SCALING PT. 5 - DISPLAY VALUE
SCALING PT. 5 - INPUT VALUE
SCALING PT. 6 - DISPLAY VALUE
SCALING PT. 6 - INPUT VALUE
SCALING PT. 7 - DISPLAY VALUE
SCALING PT. 7 - INPUT VALUE
SCALING PT. 8 - DISPLAY VALUE
SCALING PT. 8 - INPUT VALUE
SCALING PT. 9 - DISPLAY VALUE
SCALING PT. 9 - INPUT VALUE
SCALING PT. 10 - DISPLAY VALUE
SCALING PT. 10 - INPUT VALUE
RATE DISPLAY ROUNDING
MINIMUM LOW CUT OUT
MAX CAPTURE DELAY TIME
MIN CAPTURE DELAY TIME
PARAMETER
PARAMETER
FACTORY
SETTING
FACTORY
SETTING
USER SETTING
USER SETTING