MPAXD000 Red Lion Controls, MPAXD000 Datasheet - Page 4

no-image

MPAXD000

Manufacturer Part Number
MPAXD000
Description
Voltage-Current Input Module
Manufacturer
Red Lion Controls
Datasheets

Specifications of MPAXD000

Accessory Type
Analog Input Module
Signal Input Type
Selectable Voltage
No. Of Analog Outputs
5
Character Size
0.56"
Accuracy
0.03% of reading + 0.03 μA to 0.5% of reading + 0.3 μA @ 18 to 28 °C, 0.03% of reading +30 μV to 0.05% of reading +30 mV @ 18 to 28 °C, 0.05% of reading +30 Megohm to 0.05% of reading +1 Ohms @ 18 to 28 °C
Brand/series
MPAX Series
Display Type
LED
Impedance, Input
100 Ohms to 10 Kiloohms
Measuring Range
± 200 μADC to ± 2 ADC, ± 200 mVDC to ± 300 VDC, 100 Ohms to 10 Kiloohms
Resolution
10 nA to 0.1 mA, 10 μV to 10 mV, 0.01 Ohms to 1 Ohms
Standards
cULus Listed, CE Certified
Voltage, Working
85 to 250 VAC
Sealing
NEMA 4/IP65
No. Of Analog Inputs
5
Rohs Compliant
Yes
For Use With
EPAX 5 Digit Displays
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
EPAX DISPLAY INSTALLATION
into a panel or enclosure. The display is provided
with a gasket to provide a water-tight seal. The
recommended minimum panel thickness for
NEMA 4/IP65 sealing is 0.060" (1.57 mm).
cut-out to the dimensions shown in
Figure 3. The supplied template may be
used to mark the cut-out and hole
locations on the panel. After the panel
cut-out has been deburred, slide the
panel gasket over the rear of the display
and onto the mounting studs. Insert the
display into the panel cut-out as
illustrated in Figure 4. Install 14 # 10-32
keps nuts (supplied) and tighten evenly
for uniform gasket compression. Do not
over-tighten the nuts.
the EPAX can be surface-wall mounted,
suspended, or bottom mounted. Separate installation
instructions are provided with the mounting accessories.
Environment And Cleaning
the maximum operating temperature and provides good air
circulation. Placing the system near devices that generate
excessive heat should be avoided.
neutral soap product. Do NOT use solvents. Continuous
exposure to direct sunlight may accelerate the aging
process of the bezel.
2.0 INSTALLING THE DISPLAY
The EPAX display is intended to be mounted
For panel mounting, prepare the panel
By using additional mounting accessories,
The display should be installed in a location that does not exceed
The bezel should be cleaned only with a soft cloth and
DIMENSIONS In inches (mm)
Figure 3, Panel Cut-out for the EPAX
4
Figure 4, Installing The EPAX Into A Panel

Related parts for MPAXD000