BSCF NEWPORT ELECTRONICS, BSCF Datasheet - Page 53

no-image

BSCF

Manufacturer Part Number
BSCF
Description
BOARD-TRMS VOLT./CURR. - NEWPORT
Manufacturer
NEWPORT ELECTRONICS
Datasheet

Specifications of BSCF

Rohs Compliant
NA
PHTX-11 ----------Isolated 4-20 mA transmitter with integral display and NEMA 4X enclosure . . . . . . . . . . . . . . . .$430.00
PHAMP-1 ---------pH Preamplifier, single output, lithium battery powered (5-year life) encapsulated in an epoxy
PHAMP-2 ---------pH Preamplifier, 10 to 40 Vdc powered . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79.00
PHAMP-3 ---------pH Preamplifier, 10 to 40 Vdc powered with automatic temperature compensation.
HHpH1-------------Pocket pH tester . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$59.50
HHpH1-KIT -------Pocket pH tester with pH 4,7 and 10 buffer capsules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69.50
HHpH1-R----------Replacement electrode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$27.50
PH-BATT-12------1.35 V replacement batteries, 12 pack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.00
PH-BATT-1 -------1.35 V replacement battery (3 required) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.00
PHA-4--------------Buffer solution, 475 ml, pH 4.01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.00
PHA-7--------------Buffer solution, 475 ml, pH 7.01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.00
PHA-10 ------------Buffer solution, 475 ml, pH 10.01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.00
HHCD --------------Pocket Conductivity tester . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$119.00
PH-BATT-12------1.35 V replacement batteries, 12 pack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$10.00
PH-BATT-1 -------1.35 V replacement battery (3 required) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.00
CDS-45 ------------Conductivity standard solution, 45 µS/cm, 1 quart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18.00
CDS-450 ----------Conductivity standard solution, 450 µS/cm, 1 quart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18.00
CDS-1500---------Conductivity standard solution, 1500 µS/cm, 1 quart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18.00
CDS-4500---------Conductivity standard solution, 4500 µS/cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18.00
PHTX SERIES
pH, ORP TRANSMITTERS AND PREAMPLIFIERS
The PHTX series Preamps are unity gain preamplifiers which convert the high impedance mV signal of a pH
or ORP electrode to a low impedance signal which can travel 1,000 feet over ordinary wire and connectors.
They may be used with pH meters and controllers (such as the INPCpH) which include high impedance
input circuitry and also with Process Meters and and Controllers such as the INFCP and INFP. In many
applications the PHTX-20 series Preamps will also extend the useful life of expensive pH electrodes,
lowering the output impedance of an aging electrode allowing it to continue providing a measurable signal.
filled stainless steel enclosure. Input and output connections are BNC . . . . . . . . . . . . . . . . . . . . .59.00
(1000 ohm RTD is required) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129.00
MODEL HHpH1
COMBINATION POCKET pH TESTER/THERMOMETER WITH REPLACEABLE ELECTRODE
The pocket-sized tester combines the pH electrode and readout into a single, compact unit. The
electrode module contains a signal amplifier and a temperature sensor to let you take temperature
compensated readings. The electrode is easily replaced, thus extending the life of the tester. The
electrode module detaches for easy replacement or battery removal.
ACCESSORIES
MODEL HHCD
POCKET CONDUCTIVITY TESTER
Pocket size, digital conductivity meter offering a variety of measuring ranges with one model. Ideal for
quick field checks of water-based solutions, each model combines the measuring sensor and meter in
one pocket-size package. The model HHCD measures in the ranges 1 to 199µS/cm, 0.01 to 1.99mS, 0.1
to 19.9mS, 1 to 199ppm, 0.01 to 1.99ppt and 0.1 to 19.9ppt ranges, with ATC 0 to 70°C (32 to 158°F).
ACCESSORIES
53