FN-50-50 Tyco Electronics, FN-50-50 Datasheet - Page 3

Shunt

FN-50-50

Manufacturer Part Number
FN-50-50
Description
Shunt
Manufacturer
Tyco Electronics
Series
FNr
Datasheet

Specifications of FN-50-50

Current Rating
50A
Accuracy
± 0.25%
Sensing Element
Manganin
Operating Temperature Range
-20°C To +60°C
Mounting Type
Base
Terminal Type
Screw
Output Voltage
50mV
Shunt Voltage
50mV
Shunt Accuracy ±
0.25%
Lead Free Status / RoHS Status
na
Features
Accuracy 0.25%
Insulated Base mounting
Temperature Coefficient
0.002% per 1°C.
Shunts
CATALOG No AMP
FN-1.50*
FN-2.50*
FN-5.50*
FN-10.50*
FN-20.50
FN-50.50
FN-100.50
FN-150.50
FN-200.50
FN-250.50
FN-300.50
FN-400.50
FN-500.50
Specification
Ratings:
Accuracy:
Outputs:
Temperature
Coefficient:
Construction
Dimensions
50 MV
Tolerances + 0.381 mm (0.015 in) for hole diameters, other tolerances + 0.762 mm (0.030 in) unless otherwise noted.
Dimensions are subject to change without notice.
W e b : w w w . c r o m p t o n - i n s t r u m e n t s . c o m • E m a i l : c r o m p t o n . i n f o @ t y c o e l e c t r o n i c s . c o m
Based Mounted Shunts
FN Series
The manganin resistance element is hard
soldered into conservatively rated brass end
blocks. These are mounted on to an
insulating, moulded base, drilled to provide
fixing holes.
1
2
5
10
20
50
100
150
200
250
300
400
500
1-500A
0.25%
50mV (or) 100mV
Refer to Factory for other outputs
0.002% per °C overall
mm
35.05
35.05
35.05
35.05
35.05
35.05
35.05
35.05
35.05
41.40
41.40
41.40
41.40
A
in
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.63
1.63
1.63
1.63
mm
12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.7
19.05
19.05
19.05
19.05
B
in
1⁄2
1⁄2
1⁄2
1⁄2
1⁄2
1⁄2
1⁄2
1⁄2
1⁄2
3⁄4
3⁄4
3⁄4
3⁄4
This base mounted shunt provides an
alternative to the panel meter series at
ratings below 500A. Its black moulded
base gives the additional mechanical
strength required for many applications as
well as providing a means of mounting. It is
equally suitable for laboratory work for use
as a component in electronic equipment.
100 MV
CATALOG No AMP
FN-1.100
FN-2.100
FN-5.100
FN-10.100
FN-15.100
FN-20.100
FN-25.100
FN-50.100
FN-75.100
FN-100.100
FN-200.100
FN-300.100
FN-500.100
Installation
Warning
Shunts can be mounted horizontally or
vertically. For maximum heat dissipitation,
mount horizontally with the element in free air
and ensure that the equipment housing
permits adequate ventilation.
Shunts are not fully insulated and protection
against accidential contact may be necessary
in order to comply with Health and Safety
regulations.
1
2
5
10
15
20
25
50
75
100
200
300
500
mm
35.05
35.05
35.05
35.05
35.05
35.05
35.05
35.05
35.05
35.05
35.05
41.40
41.40
A
in
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.63
1.63
mm
12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.7
19.07
19.07
B
2 0 0 2
in
1⁄2
1⁄2
1⁄2
1⁄2
1⁄2
1⁄2
1⁄2
1⁄2
1⁄2
1⁄2
1⁄2
3⁄4
3⁄4

Related parts for FN-50-50