Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
MODEL LPAX- 6 DIGIT LARGE PAX DISPLAY FOR DIGITAL INPUTS
GENERAL DESCRIPTION
offering the plant floor or production area a large visual display of their current
status. Whether your measurement is rate, count, or time, the LPAX can satisfy
your requirement. These LPAX displays accept various digital inputs through
the use of input modules (MPAX) which allow the unit to adapt to most any
application. The MPAX Modules offer the same features as our highly
successful PAX Series Panel Meters. Additional plug-in option cards can add
alarms, analog output, and communication/bus capabilities, making the LPAX a
truly Intelligent Panel Meter.
SAFETY SUMMARY
corresponding literature, or on equipment, must be observed to ensure personal
safety and to prevent damage to either the instrument or equipment connected
to it. If equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
DIMENSIONS In inches (mm)
The LPAX Display is a versatile display that can increase productivity by
All safety regulations, local codes and instructions that appear in this and
installation and operation of the unit.
Read complete instructions prior to
4
CAUTION: Risk of Danger.
parts of the equipment for safety purposes and must be
connected to an external protective earthing system.
The protective conductor terminal is bonded to conductive
CAUTION: Risk of electric shock.
1
SPECIFICATIONS
1. DISPLAY: 1.5" (38 mm) Red LED
2. POWER REQUIREMENTS:
3. INPUT: Accepts digital input modules, see “Selecting Your Display
4. ANNUNCIATORS:
5. KEYPAD: Five tactile membrane switches integrated into the front panel
6. CERTIFICATIONS AND COMPLIANCES:
Additional specifications, wiring, programming, and information for the
individual MPAX models are contained in the corresponding standard PAX
literature. This PAX literature is shipped with the ordered MPAX model.
6-Digit (LPAX0600): (-99999 to 999999)
6-Digit (LPAXCK00): (0 to 999999)
AC Modules: 85 to 250 VAC, 50/60 Hz, 18 VA
DC Modules: 11 to 36 VDC or 24 VAC ±10%, 50/60 Hz, 14 W
Components and Option Cards.”
LPAX0600: A, B, C, SP1, SP2, SP3, and SP4
LPAXCK00: TMR, CNT, DAT, SP1, SP2, SP3, and SP4
SAFETY
ELECTROMAGNETIC COMPATIBILITY
ALARMS, ANALOG OUTPUT, AND COMMUNICATION
LARGE LED DISPLAY READABLE TO 70 FEET
VARIOUS DIGITAL INPUT MODULES;
PROGRAMMABLE USER INPUTS
PROGRAMMABLE FUNCTION KEYS
UNIVERSAL AC/DC POWERED MODELS
PC SOFTWARE FOR METER CONFIGURATION
NEMA 4/IP65
UL Recognized Component, File #E179259, UL61010A-1, CSA 22.2 No. 1010-1
UL Listed, File # E137808, UL508, CSA C22.2 No. 14-M95
Type 4 Enclosure rating (Face Only), UL50
IECEE CB Scheme Test Certificate # US/8843/UL
EMC specifications determined by the MPAX module.
Recognized to US and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories, Inc.
LISTED by Und. Lab. Inc. to U.S and Canadian safety standards
CB Scheme Test Report # 04ME11209-20041018
IEC 61010-1, EN 61010-1: Safety requirements for electrical
IP65 Enclosure rating (Face only), IEC 529
Issued by Underwriters Laboratories, Inc.
equipment for measurement, control, and laboratory use, Part 1.
COUNT AND RATE INPUT
CLOCK/TIMER
SERIAL SLAVE
PANEL CUT-OUT
Bulletin No. LPAX6-D
Drawing No. LP0530
Released 1/06