F3PAM-24V HOBUT, F3PAM-24V Datasheet

Analog Indicator

F3PAM-24V

Manufacturer Part Number
F3PAM-24V
Description
Analog Indicator
Manufacturer
HOBUT
Datasheet

Specifications of F3PAM-24V

Meter Function
Battery Condition Indicator
Meter Range
21V To 25V
Meter Size/dimensions
48mm X 48mm
External Width
48mm
External Depth
24mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
BATTERY CONDITION &
CHARGING INDICATORS
DESCRIPTION A range of ammeters and voltmeters
F3PAM
F3DM
11840
with tough moving magnet or
polarised moving iron movements
designed for low cost indication of
d.c. or rectified a.c.
Application: Ammeters normally used to
indicate charge or discharge currents on
vehicle battery charging systems.
Standard Range:
0/5A, 0/8A, 0/10A, 0/12A, 0/15A, 0/20A,
0/30A, 0/40A, 0/50A, 0/60A, 0/75A
8/0/8A, 12/0/12A, 30/0/30A, 50/0/50A,
60/0/60A
Calibration
accuracy:
Movement:
Temperature
range:
Terminations:
Fixing:
Options:
Application: Suppressed zero battery
condition indicators designed to monitor
the state of lead acid batteries.
Standard Range:
12V (yellow zone 10.5 to 12.5V)
24V (yellow zone 21.0 to 25.0V)
36V (yellow zone 31.5 to 38.0V)
48V (yellow zone 42.0 to 50.5V)
Calibration
accuracy:
Movement:
Temperature
range:
Terminations:
Fixing:
Options:
±8% of range
Polarised moving iron
-20ºC to +40ºC
6.3 or 4.7mm faston tags
Snap into panel
High intensity LED
indicating system on.
Black or white dial
±8% of f.s.d.
Polarised moving iron
-20ºC to +40ºC
2BA up to 20A
1/4 BSF above 20A
U clip
Illumination slots available
Black or white dial
Dimensions (mm)
Dimensions (mm)
41.5
Dia
Panel thickness
1.0 - 1.5
2.0 - 2.5
48
23.8
56
35
51
45º
48
4
Panel cutout
Panel cutout
(View from front)
4.75
9
15
20.6
X mm
51.0
52.5
38.1
40.5
Dia

Related parts for F3PAM-24V

F3PAM-24V Summary of contents

Page 1

... DESCRIPTION A range of ammeters and voltmeters with tough moving magnet or polarised moving iron movements designed for low cost indication of d.c. or rectified a.c. 11840 F3PAM F3DM Application: Suppressed zero battery condition indicators designed to monitor the state of lead acid batteries. Standard Range: 12V (yellow zone 10.5 to 12.5V) 24V (yellow zone 21 ...

Page 2

... For best results use with cable sizes 5mm to 10mm diameter The products detailed in this publication are our standard range, but for large quantity orders, HOBUT engineers will be pleased to work with customers to design individual dials to their specifications. HOWARD BUTLER LTD CROWN WORKS, LINCOLN ROAD ...

Related keywords